FC 300 Design Guide
the motor size. The latter selection can be used
to program several drives with the same function
without disturbing motor data which are already set.
Par. 0-50 cannot be adjusted while motor is running.
0-51 Set-up Copy
Option:
*
No copy
Copy to set-up 1
Copy to set-up 2
Copy to set-up 3
Copy to set-up 4
Copy to all
Function:
Select Copy to set-up 1 [1] to copy all parameters in
the current edit set-up (set in par. 0-11) to set-up
1. Make the same choice in the other parameters.
Select Copy to all [9] to make all parameters in all
set-ups to the parameters in the current edit set-up.
0-6* Password
"
This group contains the parameters that control
the password functionality.
0-60 Main Menu Password
Range:
0 - 999
Function:
Defines the password used for accessing the
Main Menu. If par. 0-61 is set to Full access
[0], this parameter is ignored.
0-61 Access to Main Menu w/o Password
Option:
*
Full access
Read only
No access
Function:
Select Full access [0] to disable the password
in par. 0-60. Select Read only [1] to block
unauthorized editing of Main Menu parameters.
Select No access [2] to block unauthorised viewing
and editing of Main Menu parameters.
If [0] Full access is selected then par. 0-66 is ignored.
0-65 Quick Menu Password
Range:
0 - 999
default setting
( )
*
140
How to Programme
[0]
[1]
[2]
[3]
[4]
[9]
[0]
[1]
[2]
display text
[ ]
value for use in communication via serial communication port
MG.33.B4.02 - VLT is a registered Danfoss trademark
Function:
Defines the password be used to access the
Quick Menu. If par. 0-66 is set to Full access
[0], this parameter is ignored.
0-66 Access to Quick Menu w/o Password
Option:
*
Full access
Read only
No access
Function:
Select Full access [0] to disable the password in par.
0-65. Select Read only [1] to block unauthorised
editing of Quick Menu parameters. Select No
access [2] to block unauthorised viewing and
editing of Quick Menu parameters.
This parameter is ignored if par. 0-61 is
set to [0] Full access.
*
100
*
200
[0]
[1]
[2]