FC 300 Design Guide
6-** Analog In/Out
"
Par.
Parameter description
No.
#
6-0* Analog I/O Mode
6-00
Live Zero Timeout Time
6-01
Live Zero Timeout Function
6-1* Analog Input 1
6-10
Terminal 53 Low Voltage
6-11
Terminal 53 High Voltage
6-12
Terminal 53 Low Current
6-13
Terminal 53 High Current
6-14
Terminal 53 Low Ref./Feedb. Value
6-15
Terminal 53 High Ref./Feedb. Value
6-16
Terminal 53 Filter Time Constant
6-2* Analog Input 2
6-20
Terminal 54 Low Voltage
6-21
Terminal 54 High Voltage
6-22
Terminal 54 Low Current
6-23
Terminal 54 High Current
6-24
Terminal 54 Low Ref./Feedb. Value
6-25
Terminal 54 High Ref./Feedb. Value
6-26
Terminal 54 Filter Time Constant
6-5* Analog Output 1
6-50
Terminal 42 Output
6-51
Terminal 42 Output Min Scale
6-52
Terminal 42 Output Max Scale
default setting
( )
*
226
How to Programme
Default value
0.000 ReferenceFeed-
1500.000 Reference-
FeedbackUnit
0.000 ReferenceFeed-
1500.000 Reference-
FeedbackUnit
[0] No operation
display text
[ ]
value for use in communication via serial communication port
MG.33.B4.02 - VLT is a registered Danfoss trademark
4-set-up
10 s
All set-ups
[0] Off
All set-ups
0.07 V
All set-ups
10.00 V
All set-ups
0.14 mA
All set-ups
20.00 mA
All set-ups
backUnit
All set-ups
All set-ups
0.001 s
All set-ups
0.07 V
All set-ups
10.00 V
All set-ups
0.14 mA
All set-ups
20.00 mA
All set-ups
backUnit
All set-ups
All set-ups
0.001 s
All set-ups
All set-ups
0.00 %
All set-ups
100.00 %
All set-ups
FC 302
Change
Conver-
only
during
sion
operation
index
TRUE
0
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-5
TRUE
-5
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-2
TRUE
-2
TRUE
-5
TRUE
-5
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-
TRUE
-2
TRUE
-2
Type
Uint8
Uint8
Int16
Int16
Int16
Int16
Int32
Int32
Uint16
Int16
Int16
Int16
Int16
Int32
Int32
Uint16
Uint8
Int16
Int16