FC 300 Design Guide
5-** Digital In/Out
"
Par.
Parameter description
No.
#
5-0* Digital I/O mode
5-00
Digital I/O Mode
5-01
Terminal 27 Mode
5-02
Terminal 29 Mode
5-1* Digital Inputs
5-10
Terminal 18 Digital Input
5-11
Terminal 19 Digital Input
5-12
Terminal 27 Digital Input
5-13
Terminal 29 Digital Input
5-14
Terminal 32 Digital Input
5-15
Terminal 33 Digital Input
5-3* Digital Outputs
5-30
Terminal 27 Digital Output
5-31
Terminal 29 Digital Output
5-4* Relays
5-40
Function Relay
5-41
On Delay, Relay
5-42
Off Delay, Relay
5-5* Pulse Input
5-50
Term. 29 Low Frequency
5-51
Term. 29 High Frequency
5-52
Term. 29 Low Ref./Feedb. Value
5-53
Term. 29 High Ref./Feedb. Value
5-54
Pulse Filter Time Constant #29
5-55
Term. 33 Low Frequency
5-56
Term. 33 High Frequency
5-57
Term. 33 Low Ref./Feedb. Value
5-58
Term. 33 High Ref./Feedb. Value
5-59
Pulse Filter Time Constant #33
5-6* Pulse Output
5-60
Terminal 27 Pulse Output Variable
5-62
Pulse Output Maximum Frequency #27
5-63
Terminal 29 Pulse Output Variable
5-65
Pulse Output Maximum Frequency #29
5-7* 24V Encoder Input
5-70
Term 32/33 Pulses per Revolution
5-71
Term 32/33 Encoder Direction
5-72
Term 32/33 Gear Numerator
5-73
Term 32/33 Gear Denominator
default setting
( )
*
How to Programme
Default value
[10] Reversing
[2] Coast inverse
[0] No operation
[0] No operation
[0] No operation
[0] No operation
[0] No operation
0.000 ReferenceFeed-
1500.000 Reference-
FeedbackUnit
0.000 ReferenceFeed-
1500.000 Reference-
FeedbackUnit
[0] No operation
[0] No operation
[0] Clockwise
display text
[ ]
value for use in communication via serial communication port
MG.33.B4.02 - VLT is a registered Danfoss trademark
4-set-up
[0] PNP
All set-ups
[0] Input
All set-ups
[0] Input
All set-ups
[8] Start
All set-ups
All set-ups
All set-ups
[14] Jog
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
0.01 s
All set-ups
0.01 s
All set-ups
100 Hz
All set-ups
100 Hz
All set-ups
backUnit
All set-ups
All set-ups
100 ms
All set-ups
100 Hz
All set-ups
100 Hz
All set-ups
backUnit
All set-ups
All set-ups
100 ms
All set-ups
All set-ups
5000 Hz
All set-ups
All set-ups
5000 Hz
All set-ups
1024 N/A
All set-ups
All set-ups
1 N/A
All set-ups
1 N/A
All set-ups
FC 302
Change
Conver-
only
during
sion
operation
index
FALSE
-
TRUE
-
x
TRUE
-
TRUE
-
TRUE
-
TRUE
-
x
TRUE
-
TRUE
-
TRUE
-
TRUE
-
x
TRUE
-
TRUE
-
TRUE
-2
TRUE
-2
x
TRUE
0
x
TRUE
0
x
TRUE
-3
x
TRUE
-3
x
FALSE
-3
TRUE
0
TRUE
0
TRUE
-3
TRUE
-3
FALSE
-3
TRUE
-
TRUE
0
x
TRUE
-
x
TRUE
0
FALSE
0
FALSE
-
FALSE
0
FALSE
0
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint16
Uint32
Uint32
Int32
Int32
Uint16
Uint32
Uint32
Int32
Int32
Uint16
Uint8
Uint32
Uint8
Uint32
Uint16
Uint8
Uint16
Uint16
225