FC 300 Design Guide
NB!:
This parameter is not visible via LCP.
9-65 Profile Number
Option:
Read only
0 - 0
Function:
Contains the profile identification. Byte 1
contains the profile number and byte 2 the
version number of the profile.
NB!:
This parameter is not visible via LCP.
9-71 Save Data Values
Option:
*
Off
Store edit setup
Store all set-ups
Function:
Parameter values changed via Profibus are not
automatically stored into non-volatile memory. Use
this parameter to activate a function that stores all
parameter values in the EEPROM. Thus, you retain
changed parameter values at power-down.
- [0] Off: The store function is inactive.
- [1] Store edit set-up: All parameter values
in the set-up selected in par. 9-70 are
stored in the EEPROM.
The value returns to [0] Off when all
values are stored.
-[2] Store all set-ups: All parameter values for all
set-ups are stored in the EEPROM. The value returns
to [0] Off when all parameter values are stored.
9-70 Edit Set-up
Option:
Factory setup
*
Setup 1
*
Setup 2
*
Setup 3
*
Setup 4
Active setup
Function:
Edit set-up. Editing can either follow the active
set-up selection (par. 0-10) or be fixed at a set-up
number. This parameter is unique for LCP and buses.
default setting
( )
*
188
How to Programme
[0]
[1]
[2]
[0]
[1]
[2]
[3]
[4]
[9]
display text
[ ]
value for use in communication via serial communication port
MG.33.B4.02 - VLT is a registered Danfoss trademark
9-72 Drive Reset
Option:
*
No action
Power-on reset
Comm. option reset
Function:
Resets the drive (as for power-cycle). The drive
*
0
disappears from the bus, which might cause a
communication error from the master.
9-80 Defined Parameters (1)
Array [116]
Option:
No LCP access
Read only
0 - 115
Function:
Holds a list of all the defined drive parameters
available for Profibus.
9-81 Defined Parameters (2)
Array [116]
Option:
No LCP access
Read only
0 - 115
Function:
Holds a list of all the defined drive parameters
available for Profibus.
9-82 Defined Parameters (3)
Array [116]
Option:
No LCP access
Read only
0 - 115
Function:
Holds a list of all the defined drive parameters
available for Profibus.
9-83 Defined Parameters (4)
Array [116]
Option:
No LCP access
[0]
[1]
[3]
*
0
*
0
*
0