User Motor Parameters - ABB ACQ80-04 Firmware Manual

Drives for water, standard control program
Table of Contents

Advertisement

No.
Name/Value
98
98 User motor
parameters
98.01
User motor model
mode
Not selected
Motor parameters
98.02
Rs user
0.00000...0.50000
p.u.
98.03
Rr user
0.00000...0.50000
p.u.
98.04
Lm user
0.00000...10.00000
p.u.
98.05
SigmaL user
0.00000...1.00000
p.u.
98.06
Ld user
0.00000 ...
10.00000 p.u
98.07
Lq user
0.00000 ...
10.00000 p.u
98.08
PM flux user
0.00000 ... 2.00000
p.u
Description
Motor values supplied by the user that are used in the motor
model.
These parameters are useful for non-standard motors, or to
just get more accurate motor control of the motor on site. A
better motor model always improves the shaft performance.
Activates the motor model parameters 98.02...98.12.
Notes:
• Parameter value is automatically set to zero when ID run is
selected by parameter
of parameters
98.02...98.12
the motor characteristics identified during the ID run.
• Measurements made directly from the motor terminals
during the ID run are likely to produce slightly different
values than those on a data sheet from a motor
manufacturer.
• This parameter cannot be changed while the drive is
running.
Parameters
98.02...98.12
The values of parameters 98.02...
motor model.
Defines the stator resistance R
With a star-connected motor, R
winding. With a delta-connected motor, R
resistance of one winding.
Stator resistance in per unit.
Defines the rotor resistance R
Rotor resistance in per unit.
Defines the main inductance L
Main inductance in per unit.
Defines the leakage inductance
Leakage inductance in per unit.
Defines the direct axis (synchronous) inductance.
Note: This parameter is valid only for permanent magnet
motors.
Direct axis inductance in per unit.
Defines the quadrature axis (synchronous) inductance.
Note: This parameter is valid only for permanent magnet
motors.
Quadrature axis inductance in per unit.
Defines the permanent magnet flux.
Note: This parameter is valid only for permanent magnet
motors.
Permanent magnet flux in per unit.
99.13 ID run
requested. The values
are then updated according to
inactive.
98.12
are used as the
of the motor model.
S
is the resistance of one
S
is one-third of the
S
of the motor model.
R
of the motor model.
M
σ
L
.
S
Parameters 173
Def/FbEq16
Not selected
0
1
0.00000 p.u.
-
0.00000 p.u.
-
0.00000 p.u.
-
0.00000 p.u.
-
0.00000 p.u.
-
0.00000 p.u.
-
0.00000 p.u.
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents