ABB ACQ80-04 Firmware Manual page 145

Drives for water, standard control program
Hide thumbs Also See for ACQ80-04:
Table of Contents

Advertisement

No.
Name/Value
Speed
Frequency
50.08
FBA A actual 2 type
50.09
FBA A SW
transparent source
Not selected
Other
50.10
FBA A act1
transparent source
Not selected
Other
50.11
FBA A act2
transparent source
50.12
FBA A debug mode
Disable
Fast
50.13
FBA A control word
0.0.0.0.0...FF.FF.FF
.FF
50.14
FBA A reference 1
-2147483648...
2147483647
50.15
FBA A reference 2
50.16
FBA A status word
0.0.0.0.0...FF.FF.FF
.FF
50.17
FBA A actual value
1
-2147483648...
2147483647
Description
The scaling is defined by parameter
speed.
The scaling is defined by parameter
frequency.
Not applicable
Selects the source of the fieldbus status word when
parameter
50.06 FBA A SW sel
No source selected.
Source selection (see
Terms and abbreviations
When parameter
50.07 FBA A actual 1 type
Transparent, this parameter selects the source of actual value
1 transmitted to the fieldbus network through fieldbus adapter
A.
No source selected.
Source selection (see
Terms and abbreviations
Not applicable
This parameter enables debug mode. Shows raw
(unmodified) data received from and sent to fieldbus adapter
A in parameters 50.13...50.18.
Debug mode disabled.
Debug mode enabled. Cyclical data update is as fast as
possible which increases CPU load on the drive.
Shows raw (unmodified) control word sent by the master
(PLC) to fieldbus adapter A if debugging is enabled by
parameter
50.12 FBA A debug
This parameter is read-only.
Control word sent by master to fieldbus adapter A.
Displays raw (unmodified) reference REF1 sent by the master
(PLC) to fieldbus adapter A if debugging is enabled by
parameter
50.12 FBA A debug
This parameter is read-only.
Raw REF1 sent by master to fieldbus adapter A.
Not applicable.
Shows raw (unmodified) status word sent by fieldbus adapter
A to the master (PLC) if debugging is enabled by parameter
50.12 FBA A debug
mode.
This parameter is read-only.
Status word sent by fieldbus adapter A to master.
Shows raw (unmodified) actual value ACT1 sent by fieldbus
adapter A to the master (PLC) if debugging is enabled by
parameter
50.12 FBA A debug
This parameter is read-only.
Raw ACT1 sent by fieldbus adapter A to master.
99.09 Motor nominal
99.08 Motor nominal
is set to
Transparent
mode.
on page 64).
is set to
on page 64).
mode.
mode.
mode.
Parameters 145
Def/FbEq16
4
5
Not selected
-
-
Not selected
-
-
Disable
0
1
0.0.0.0
-
0
0
0.0.0.0
-
0
-