ABB ACQ80-04 Firmware Manual page 91

Drives for water, standard control program
Table of Contents

Advertisement

No.
Name/Value
AO has automatic scaling. Every time the source for the AO is changed, the scaling range is
changed accordingly. User given minimum and maximum values override the automatic values.
13.12 AO1
13.22 AO2 source
0
Zero
1
Motor speed used
3
Output frequency
4
Motor current
5
Motor current % of motor
nominal
6
Motor torque
7
DC voltage
8
Output power
12
Speed ref used
14
Freq ref used
16
Process PID out
20
Temp sensor 1 excitation
21
Temp sensor 2 excitation
26
Abs motor speed used
27
Abs motor speed %
28
Abs output frequency
30
Abs motor torque
31
Abs output power
32
Abs motor shaft power
37
AO1 data storage
38
AO2 data storage
Other
-32768.0...32767.0
13.18
AO1 source max
-32768.0...32767.0
13.19
AO1 out at AO1 src
min
0.000...22.000 mA /
0.000...11.000 V
13.20
AO1 out at AO1 src
max
0.000...22.000 mA /
0.000...11.000 V
Description
source,
13.17 AO1 source
13.27 AO2 source min
N/A (Output is constant zero.)
0
0
0
0%
0
Min. value of
voltage
0
0
0
Min. value of
PID output actual
N/A (Analog output is not scaled; it is determined by the
sensor's triggering voltage.)
0
0
0
0
0
0
13.91 AO1 data storage
93).
13.92 AO2 data storage
93).
Min. value of the selected
Real signal value corresponding to minimum AO1 output
value.
Defines the real maximum value of the signal (selected by
parameter
13.12 AO1
maximum required AO1 output value (defined by parameter
13.20 AO1 out at AO1 src
source
min.
Real signal value corresponding to maximum AO1 output
value.
Defines the minimum output value for analog output AO1.
See also drawing at parameter
Minimum AO1 output value.
Defines the maximum output value for analog output AO1.
See also drawing at parameter
Maximum AO1 output value.
min,
13.18 AO1 source
13.28 AO2 source max
99.09 Motor nominal speed
99.08 Motor nominal
frequency
30.17 Maximum current
100%
46.03 Torque scaling
01.11 DC
Max. value of
voltage
46.04 Power scaling
99.09 Motor nominal speed
99.08 Motor nominal
frequency
40.01 Process
Max. value of
PID output actual
99.09 Motor nominal speed
99.09 Motor nominal speed
99.08 Motor nominal
frequency
46.03 Torque scaling
46.04 Power scaling
46.04 Power scaling
(page
13.91 AO1 data storage
(page
13.92 AO2 data storage
Max. value of the selected
source) that corresponds to the
max). See parameter
13.17 AO1 source
13.17 AO1 source
Parameters 91
Def/FbEq16
max,
01.11 DC
40.01 Process
1 = 1
50.0
13.17 AO1
1 = 1
0.000 mA
min.
1000 = 1 mA
20.000 mA
min.
1000 = 1 mA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents