152 Parameters
No.
Name/Value
58.17
Transmit delay
0...65535 ms
58.18
EFB control word
0000h...FFFFh
58.19
EFB status word
0000h...FFFFh
58.25
Control profile
ABB Drives
DCU Profile
58.26
EFB ref1 type
Speed or frequency Type and scaling is chosen automatically according to the
Transparent
General
Torque
Speed
Frequency
58.27
EFB ref2 type
58.28
EFB act1 type
Description
Defines a minimum response delay in addition to any fixed
delay imposed by the protocol.
Changes to this parameter take effect after the control unit is
rebooted or the new settings validated by parameter
Communication control (Refresh
Minimum response delay.
Shows raw (unmodified) status word sent by the drive to the
Modbus controller. For debugging purposes.
This parameter is read-only.
Control word sent by Modbus controller to the drive.
Shows raw (unmodified) status word for debugging purposes.
This parameter is read-only.
Status word sent by the drive to the Modbus controller.
Defines the communication profile used by the protocol.
Changes to this parameter take effect after the control unit is
rebooted or the new settings validated by parameter
Communication control (Refresh
ABB Drives control profile (with a 16-bit control word)
DCU control profile (with a 16 or 32-bit control word)
Selects the type and scaling of reference 1 received through
the embedded fieldbus interface.
The scaled reference is displayed by
Note: Applicable only when
disabled. If parameter MPPT reference is enabled, then the
parameter should be set to it's default value.
currently active operation mode as follows.
Operation mode
Speed control
Frequency control
No scaling is applied.
Generic reference without a specific unit. Scaling: 1 = 100.
Torque reference. The scaling is defined by parameter
Torque
scaling.
Speed reference. The scaling is defined by parameter
Speed
scaling.
Frequency reference. The scaling is defined by parameter
46.02 Frequency
scaling.
Not applicable.
Selects the type of actual value 1.
Note: Applicable only when
disabled. If parameter MPPT reference is enabled, then the
parameter should be set to it's default value.
settings).
settings).
03.09 EFB reference
79.40 MPPT reference
is
Reference 1 type
Speed
Frequency
79.40 MPPT reference
is
Def/FbEq16
0 ms
58.06
1 = 1
-
1 = 1
-
1 = 1
ABB Drives
58.06
0
5
Speed or
frequency
1.
0
1
2
46.03
3
46.01
4
5
Speed or
frequency