158 Parameters
No.
Name/Value
Other [bit]
79.18
Tank high sensor
79.31
Pump start time
00:00:00...
23:59:59
79.32
Pump stop time
00:00:00...
23:59:59
79.40
MPPT reference
Disable
Enable
DI1
DI2
DI3
DI4
DI5
DI6
Other [bit]
79.41
Start DC voltage
225...800 V
79.42
PV cell min voltage
225...800 V
79.43
PV cell max voltage
225...800 V
79.51
Pump minimum
speed
0...3000 rpm
Description
Source selection (see
Terms and abbreviations
Selects the source for tank high level sensor enable signal.
0 = Not selected.
1 = Selected.
See parameter
79.17 Tank low
Defines the pump start time. This feature is used with timed
function.
Note: Timed function must be enabled to use this feature.
See parameter
79.10 Operating
Pump start time.
Defines the pump stop time. This feature is used with timed
function.
Note: Timed function must be enabled to use this feature.
See parameter
79.10 Operating
Pump stop time.
Selects the source for MPPT reference enable signal.
0 = Disabled
1 = Enabled
MPPT reference is not activated.
MPPT reference is activated.
Digital input DI1
(10.02 DI delayed
Digital input DI2
(10.02 DI delayed
Digital input DI3
(10.02 DI delayed
Digital input DI4
(10.02 DI delayed
Digital input DI5
(10.02 DI delayed
Digital input DI6
(10.02 DI delayed
Source selection (see
Terms and abbreviations
Defines the minimum DC voltage to start the drive.
Note: If you change this value while the inverter is
running, the changed value is effective only during the
next start
DC voltage.
Defines the minimum DC voltage below which the
drive cannot operate.
Note: The drive stops operating below this voltage.
DC voltage.
Defines the maximum DC voltage. At any value above
this voltage, the drive trips due to
fault.
DC voltage.
Defines the minimum motor speed. At any value below
this speed, the drive stops functioning and auto
restarts after the time defined in
setting avoids unnecessary operation of pump at low speed.
Speed.
on page 64).
sensor.
mode.
mode.
status, bit 0).
status, bit 1).
status, bit 2).
status, bit 3).
status, bit 4).
status, bit 5).
on page 64).
D4B1 PV max volt
79.61 Fault reset
time. This
Def/FbEq16
-
DI6
00:00:00
1 = 1
00:00:00
1 = 1
Enable
0
1
2
3
4
5
6
7
-
225
1 = 1
225
1 = 1
800
1 = 1
200
1 = 1