ABB ACQ80-04 Firmware Manual page 69

Drives for water, standard control program
Table of Contents

Advertisement

No.
Name/Value
01.51
Previous hour kWh
0.00... 1000000.00
kWh
01.52
Current day kWh
0.00... 1000000.00
kWh
01.53
Previous day kWh
0.00... 1000000.00
kWh
01.54
Cumulative inverter
energy
-200000000.0...
200000000.0 kWh
01.55
Inverter GWh
counter (resettable)
0...65535 GWh
01.56
Inverter MWh
counter (resettable)
0...1000 MWh
01.57
Inverter kWh
counter (resettable)
0...1000 kWh
01.58
Cumulative inverter
energy (resettable)
-200000000.0...
200000000.0 kWh
Description
Shows previous hour energy consumption.
The value
01.50 Current hour kWh
values has been cumulated for 60 minutes. The value is set
to the value before the power cycle when the drive is again up
and running.
Energy.
Shows current day energy consumption. This is the energy of
the last 24 hours (not necessarily continuous) the drive has
been running, not the energy of a calendar day.
The value is set to the value before the power cycle when the
drive is again up and running.
Energy.
Shows previous day energy consumption.
The value
01.52 Current day kWh
value has been cumulated for 24 hours. The value is set to
the value before the power cycle when the drive is again up
and running.
Energy.
Amount of energy that has passed through the drive (in either
direction) in full kilowatt-hours. The minimum value is zero.
Energy in kWh.
Amount of energy that has passed through the drive (in either
direction) in full gigawatt-hours. The minimum value is zero.
You can reset the value by setting it to zero. Resetting any of
parameters
01.55...01.58
Energy in GWh.
Amount of energy that has passed through the drive (in either
direction) in full megawatt-hours. Whenever the counter rolls
over,
01.55 Inverter MWh counter (resettable)
The minimum value is zero.
You can reset the value by setting it to zero. Resetting any of
parameters
01.55...01.58
Energy in MWh.
Amount of energy that has passed through the drive (in either
direction) in full kilowatt-hours. Whenever the counter rolls
over,
01.56 Inverter kWh counter (resettable)
The minimum value is zero.
You can reset the value by setting it to zero. Resetting any of
parameters
01.55...01.58
Energy in kWh.
Amount of energy that has passed through the drive (in either
direction) in full kilowatt-hours. The minimum value is zero.
You can reset the value by setting it to zero. Resetting any of
parameters
01.55...01.58
Energy in kWh.
is stored here when its
is stored here when its
resets all of them.
is incremented.
resets all of them.
is incremented.
resets all of them.
resets all of them.
Parameters 69
Def/FbEq16
-
1 = 1 kWh
-
1 = 1 kWh
-
1 = 1 kWh
-
10 = 1 kWh
-
1 = 1 GWh
-
1 = 1 MWh
-
10 = 1 kWh
-
10 = 1 kWh