Installation Manual
MMI-20058013
3.3
Barriers verified by Micro Motion
The following table lists the barriers that Micro Motion has verified with the 4200
transmitter. For other barriers, refer to the manufacturer's data sheet.
Table 3-1: Barriers verified by Micro Motion
Vendor
Micro Motion
Pepperl & Fuchs
Pepperl & Fuchs
MTL
MTL
MTL
MTL
MTL
MTL
MTL
STAHL
PR Electronics
3.4
Channel power requirements
The supply voltage required by the 4200 transmitter depends on the total resistance in the
mA loop. This includes all sense resistance and wire resistance.
Channel A mA HART terminal requirements
Use the chart below to determine the required supply voltage for Channel A based on loop
resistance.
Installation Manual
Barrier
505
KFD2-STC1-EX1
KFD2-STC4-EX1
787S+
7707P+
7787+
5042
3046B
7728P+
4541
9002/13-280-110-00
5106
Wiring the channels
April 2023
23