INSTALLING THE EARTH GROUND

An earth ground refers to the grounding rod and
accompanying equipment ground which need
to be installed to safeguard against potential
electrical shock and damage to personnel and
equipment.
DANGER
The potential for lightning discharge exists with
all gates, fences and gate operators. National
Electric Code (NEC) - Article 250 requires
a separate earth ground in addition to the
required equipment ground.
HySecurity recommends grounding the operator
with a separate earth ground rod (or a similar
device in the case of crash products) to shield
the operator against electromagnetism and other
electrical signals that may cause, erratic operation
with, or damage to, the Smart DC Controller and
other electrical parts.
For earth grounding requirements in the U.S.A.,
refer to the National Fire Protection Association
(NFPA) 780 - Standard for the Installation of
Lightning Protection Systems. Highlights of the
standard include:
NOTICE
Properly grounding the gate operator is critical
to gate operator performance and the life of
its electrical components. Use sufficient wire
size during installation. If you do not ground
the operator with a separate earth ground, you
risk voiding the HySecurity Warranty.
39
| www.hysecurity.com
Take the following steps to comply with NEC and
NFPA 780 standards:
1. Install a grounding rod per local building
2. Attach a large earth ground wire (6AWG) from
z New site: Run the 6AWG wire through the
z Existing site: Run the 6AWG wire beneath the
Properly grounding the gate operator is critical
to gate operator performance and the life of its
electrical components. Use sufficient wire size
during installation. Refer to "Wiring 115VAC
Power" and "Wiring 208/230VAC Power".
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
codes. See Figure 17.
the grounding rod to the lug nut on the base
of the chassis.
concrete base and into the cutout on the chassis
base.
rear cover. Make sure the covers align and side
latches lock properly.
3 ft
Consult local
codes for
proper depth.
Figure 17. Installing Earth Ground

POWER

Lug Nut
Run ground
wire through
concrete base.
MX3640-01 REV. D ©2018