Display
DG 0 (OFF)
Dual Gate
SG 0 (OFF)
Sequenced Gate
CH 0 (AC)
Charger Type
BT 0 (STANDARD)
Battery Type
70
| www.hysecurity.com
Table 12. Smart DC Controller - Installer Menu Functions
Setting Options
(Bold = Factory
Settings)
0 = solo operator
1 = Secondary unit
2 = Primary unit
3 = Sally Port A
4 = Sally Port B
0 = solo operator
1 = Loop View #1
2 = Loop View #2
3 = Loop View #3
4 = Loop View #4
0 = AC powered
1 = Solar powered
0 = standard (8Ah)
1 = extended
(50Ah)
2 = maximum
(110Ah)
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
DISPLAY AND MENU OPTIONS
Menu Tasks and Explanations
Configures gate operator as a Primary
or as a Secondary in a dual-gate
installation. When you assign one unit
as Primary, you must configure other as
Secondary through Installer Menu. This
menu is also used to configure a Sally
Port system by setting one operator to
Sally Port A and the other to Sally Port B.
Establishes communication after wiring
two or more gate operators as sequential
gates. This SG menu item only appears
if the Dual Gate menu item (DG) is set
to 0 (solo operator).
NOTE: After selecting SG settings,
consider accessing the User Menu in
each gate operator to address the Close
Timer (CT) setting.
Assigns charger type usually set at
factory. If set to solar at factory then this
menu item is hidden.
Assign battery type used by operator.
NOTE: Smaller batteries are charged
with less current to avoid overheating
and larger batteries are charged with
more current to supply a more rapid
charge.
Associated
DC Controller
Display
Connections
3-wire
shielded cable
to DUAL
GATE input
terminals.
Connect Dual
Gate COM
(Gate 1) to
Dual Gate
COM (Gate 2).
Pair wires:
A - A, COM
- COM, and
B - B
3-wire
shielded cable
to DUAL
GATE input
terminals
on both
operators. Pair
wires: A - A,
COM - COM,
and B - B
(N/A)
Extended
(50Ah)
batteries
require wire
extensions.
Maximum
(110Ah)
batteries
require
separate
housing and
wiring.