HySecurity SwingSmart DC Series Programming And Operations Manual page 126

Pad-mounted electromechanical swing gate operator with smart dc controller
Table of Contents

Advertisement

Display
Condition
HYSECURITY
LOADER
ALERT 1 FORCE
OPEN
ALERT 2
DRIFT CLOSED
ALERT 3 EXCESS
DRIFT
ALERT 4 MOTOR
OVERLOAD
ALERT 5 BOTH
LIM ACTIVE
126
| www.hysecurity.com
Table 22. Smart DC Controller - Troubleshooting
Description
Alert, Error or
Fault
Software is
being loaded
Software is currently being loaded.
into Smart DC
Controller.
Gate has been forced open from a full
Gate forced open.
close limit and is being prevented from
re-closing.
Gate has drifted closed from a full
G a t e d r i f t e d
open limit and is being prevented from
closed.
re-opening.
G a t e d r i f t i n
Alert appears if gate drifts three times
transit - Advisory
in a five minute period.
only
Thermal overload
Motor drive heat sink exceeds 195°F.
alert. When alert
Alert will temporarily disable operator,
is triggered, gate
but will automatically reset itself when
can only "fully
it cools down. May also occur if the
open" until alert
heatsink temperature is 70°F. higher
is cleared.
than ambient temperature.
Possible causes:
Both limit switches
z Short in wiring
are on at the same
z Stuck limit switch
time
z Debris in limit plate area (SwingSmart
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
Possible Causes
DC)
REFERENCE
Solutions
Wait for software to
finish loading.
Will self-clear after an
open or close input.
Will self-clear after an
openor close input.
Check track to make
sure it is level.
Check gate hardware,
weight/length of gate.
Alert automatically
c l e a r s
w h e n
t emper at ure d rop s
below threshold.
z Repair any wiring
issues.
z Check limit switches
and replace as
required.
MX3640-01 REV. D ©2018

Advertisement

Table of Contents
loading

This manual is also suitable for:

Swingsmart dcs20Swingsmart dc20

Table of Contents