Table 15. User-Programmable User Relays - Function Options
No.
Name
External Latching Gate
23
Lock Output
Gate at Partial Open
24
Position
25 DC Power Alert
Free Exit Loop
26
Detector pulse
Not Open (w/ AC
27
power)
28 Flasher (w/ AC power)
Arm Entry Ticket
29
Dispenser
Arm Exit Ticket
30
Dispenser
Resert Ticket Dispenser
31
Pulse
32 Backoff Pulse
33 Transient In Pulse
34 Transient Out Pulse
35 Tenant In Pulse
36 Tenant Out Pulse
37 Special In Pulse
38 Special Out Pulse
39 Unknown In Pulse
40 Unknown Out Pulse
41 Test Open Pulse
Break-Away Switch
42
Output
43 Warn Before
Partial Open Limit
44
Pulse
Outside Obstruction/
45
Arming Loop Detector
96
| www.hysecurity.com
Not functional in SwingSmart DC operators.
Not functional in SwingSmart DC operators.
Active when on AC power or the battery voltage is above 21V. When
used with User Relay 2, this option can shed electrical loads to conserve
battery energy.
Outputs a 250ms pulse when the free exit vehicle detector is tripped.
Activated when gate is not on open limit and AC power is present.
Deactivated when AC power fails or gate is on open limit.
Output identical to relay #19 and pulses relay 500 ms/sec when gate not
on open limit and AC power is present. Deactivated when AC power
fails or gate is on open limit.
Not functional in SwingSmart DCt operator.
Not functional in SwingSmart DC operator.
Not functional in SwingSmart DC operator.
Not functional in SwingSmart DC operator.
Not functional in SwingSmart DC operator.
Not functional in SwingSmart DC operator.
Not functional in SwingSmart DC operator.
Not functional in SwingSmart DC operator.
Not functional in SwingSmart DC operator.
Not functional in SwingSmart DC operator.
Not functional in SwingSmart DC operator.
Not functional in SwingSmart DC operator.
Output pulses five seconds after close limit is activated. Typically used
for cycle testing.
Activates when arm break-away switch is tripped.
Combination of relays #5 and #16.
Pulses for 250ms when gate, commanded with Partial Open input,
reaches Partial Open Limit, or, gate is past Partial Open Limit and Partial
Open input is activated.
Activated when OOLD/OALD detector input tripped and gate closed.
Used for testing purposes.
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL