Table 22. Smart DC Controller - Troubleshooting
Description
Alert, Error or
Fault
S m a r t
D C
Caused by a fault within HY-5B. This
C o n t ro l l e r h a s
message will also indicate which
d e t e c t e d
a
detector alert applies to: Exit Loop
problem within
(ELD), Inside Obstruction Loop (IOLD),
an HY-5B vehicle
Outside Obstruction Loop (OOLD), or
detector.
Center Loop (CLD) - (User Relay 22).
Caused when Smart DC Controller
Smart DC
sees an active loop for more than
Controller has an
5 minutes. "Active" loop can be
active loop input
actual or false. This message will
(HY-5B or box
also indicate which detector alert
detector output)
applies to: Exit Loop (ELD), Inside
for more than 5
Obstruction Loop (IOLD), Outside
minutes.
Obstruction Loop (OOLD), or Center
Loop (CLD) - (User Relay 22).
S m a r t
D C
C o n t ro l l e r h a s
Caused by degrading gate hardware
detected a gate
or debris in track. This alert appears in
that, over time,
history log. It does not have any effect
has taken more
with regard to opening or closing gate.
power to move
than it used to.
S m a r t
D C
C o n t ro l l e r h a s
Caused by broken gate hardware or
detected that it
ice/snow buildup.
cannot move gate
at all.
Target magnet
on the chain
Target magnet fell off or target sensor
is missing or
wires are damaged.
has not been
detected.
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
Possible Causes
REFERENCE
Solutions
Remove and re-install
the HY-5B and press
RESET. Replace HY-5B,
if necessary.
Check traffic patterns
at site. Loop and lead
in wires should be
checked for problems
or replaced.
Check and correct gate
hardware as required.
Check and correct gate
hardware as required.
1. Make sure target is
properly fastened to
chain.
2. Check target
sensor to make
sure it is reading
magnet. Change
sensor if it or
its wires are
damaged.