Vehicle Detector And Loop Fault Diagnostics - HySecurity SwingSmart DC Series Programming And Operations Manual

Pad-mounted electromechanical swing gate operator with smart dc controller
Table of Contents

Advertisement

VEHICLE DETECTOR AND LOOP FAULT DIAGNOSTICS

If HySecurity HY-5B vehicle detector modules are used, the Smart DC Controller has the ability to store
and report detector and loop fault information for performance diagnostics.
If the Smart DC Controller senses a loop or detector problem:
z The LCD display flashes the name of the affected detector or error and the appropriate alert code.
z The buzzer chirps continuously at regular intervals until the issue is resolved.
Alert or
LCD
Error #
Description
FREQ SHIFT
ALERT 7
FAULT
LOOP
ALERT 8
SHORTENED
ALERT 9 LOOP OPEN
A L E R T
I2C BUS
10
ERROR
A L E R T
DETECTOR
11
FAULT
A L E R T
ON TOO
12
LONG
DETECTOR
ERROR 3
FAILED
113
| www.hysecurity.com
Table 19. HY-5B Vehicle Detector Faults and Errors
Advisory
HY-5B vehicle detector
- Abnormal frequency
change alert.
HY-5B vehicle detector -
Loop is shorted.
HY-5B vehicle detector -
Disconnected loop alert.
HY-5B vehicle detector -
Communications alert.
HY-5B vehicle detector -
Malfunction alert.
Detector input triggered
too long - More than five
minutes.
HY-5B vehicle detector
- Communication failed.
Smart DC Controller will
behave as if detector is
triggered, usually holding
gate fully open.
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
Resolution
Alert indicates an unstable loop frequency. Check
loop and lead in wires for problems. Replace
them, if necessary.
Alert indicates that loop and lead in wires are
shorting out. Check wires for problems. Replace
them, if necessary.
Alert indicates loop wires are loose or
disconnected. Check wires for problems. Replace
them, if necessary.
Alert indicates detector is not communicating
properly with Smart DC Controller. Alert occurs if
detector is unplugged or connection is unstable.
If communication is not reestablished within
30 seconds, controller will reset and message
changes to ERROR 3.
Display indicates HY-5B detector malfunction.
Check detector for problems. Replace it, if
necessary.
Display indicates HY-5B detector malfunction.
It alert also works for any input connected to
terminal strip for standard box detectors. Check
that a vehicle is not parked on loop. Also,
determine if loop is stable. An unstable loop can
hold detector in a triggered state.
Alert indicates detector is not communicating
properly with Smart DC Controller. Alert occurs
if detector is unplugged or detector has failed.
To replace detector, press RESET button to clear
error and re-seat detector or install a new one.
REFERENCE
MX3640-01 REV. D ©2018

Advertisement

Table of Contents
loading

This manual is also suitable for:

Swingsmart dcs20Swingsmart dc20

Table of Contents