HySecurity SwingSmart DC Series Programming And Operations Manual page 63

Pad-mounted electromechanical swing gate operator with smart dc controller
Table of Contents

Advertisement

User Menu
Display
CT 0 (OFF)
Close Timer
HC 0 (OFF
Hold to Close
HO 0 (OFF)
Hold to Open
AP 0 AC LOSS
UPS FAIL OPEN
RO 0 (OFF)
Radio Open/Close
63
| www.hysecurity.com
Table 11. Smart DC Controller - User Menu Functions
Setting Options
(Bold = Factory
Settings)
0 = Timer
disabled
1 second to 99
seconds
0 = off
1 = on
0 = off
1 = on
0 = UPS Fail
Open
1 = UPS Fail
Close
2 = Auto Open
3 = No Close
Timer
0 = off
1 = on
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
DISPLAY AND MENU OPTIONS
Menu Tasks and Explanations
Assign how many seconds before open
gate initiates automatic closure. Keep
setting at 0 if a hard-wired, push-button
control device is being used.
NOTE: CLOSE TIMER display does not
appear when HOLD TO CLOSE is set to 1.
Set to 0 produces a gate closure when a
momentary signal is transmitted. Set to
1 if a constant hold to close signal, such
as a push button control, is being used.
A setting of 1 also deactivates automatic
close timer and causes its menu to
disappear. You must set HC to 1 to comply
with UL 325 Type D protection. Refer to
Table Notes.
Similar to HOLD TO CLOSE, but configures
OPEN push button for a constant-hold
function.
0 = Momentary open signal
1 = Constant hold open push button
required. You must set HO to 1 to comply
with UL 325 Type D protection. Refer to
Table Notes
Setting designates what action gate
performs during an AC power loss. Refer
to "Setting AC Power Loss Gate Function"
on page 61.
Configures radio input for open only (0). If
changed to setting 1 then adds capability
for radio input to close gate, but only when
gate is fully open.
Associated
DC Controller
Connections
Not applicable
(N/A)
COM
CLOSE
COM
OPEN
N/A.
COM
RADIO OPEN
MX3640-01 REV. D ©2018