Gate operator will not automatically cycle the
gate unless an indication that the appropriate
number of external entrapment protection
sensors are connected and operational.
The normally closed (NC) entrapment protection
sensors wired to the Controller's SENSOR
inputs are monitored using HySecurity software.
Prompts appear on the display requesting specifi c
confi gurations based on the gate operator type.
The following sensors have been shown in
testing to provide the best performance when
installed with HySecurity operators. HySecurity
supports installers who install these sensors. Other
"Compatible Sensors" may meet UL 325 7th
Photo Eyes (Retrorefl ective)
Photo Eyes (Thru-Beam)
Edge Sensors
Edge Sensor, Converters
(10K to NC Contact)
Edge, Wireless Kits
Multi-Input Module
19
| www.hysecurity.com
Table 1. Sensors Tested for Use with HySecurity Operators
Mfg. Part #
E3K-R10K4-NR
NIR-50-325
IRB-RET
E-931-S50RRGQ
IRB-MON
E-960-D90GQ
Sentir Series
CPT210-2U-#-T2
Hy2NC
iGAZE RE Kit
WEL-200 (kit
with receiver and
transmitter)
The Solution –
MIM-62
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
SAFETY INFORMATION
edition requirements but have not been certifi ed
for use with HySecurity operators. Contact the
sensor manufacturer for specifi c recommendations
for use.
CAUTION
External entrapment protection sensors must
have NC sensor outputs and be wired to the
SENSOR COM terminal for monitoring and
powering purposes. Depending on software
version, the sensor becomes powered when
the gate operator's motor runs or is always
powered when the operator is connected to
AC power.
Mfg.
Details
Omron
40 ft max range limit
EMX
45 ft max range limit
EMX
53 ft max range limit
Seco-Larm
46 ft max range limit
EMX
65 ft max range limit
Seco-Larm
90 ft max range limit
Channel mount, high
profi le
Channel mount, low
ASO Safety
profi le
Round, wraparound
Square, wraparound
10k resistor termination
Miller Edge
(replace # with length
requirement in feet)
2-channel edge
HySecurity
converter
Transmitter
50 ft line of sight max
Solutions
range limit
200 ft line of sight max
EMX
range limit
Miller Edge
6 inputs to 2 outputs
Hysecurity Part #
MX000999
MX3990
AS1502-0440-05
AS1502-0430-05
AS1501-0760
AS1501-0790
MX4018
MX3987
MX3640-01 REV. D ©2018