HySecurity SwingSmart DC Series Programming And Operations Manual page 57

Pad-mounted electromechanical swing gate operator with smart dc controller
Table of Contents

Advertisement

Display
Build Year
Software Version
A lower case "h"
appears in front of
the software version
number.
Dual Gate or
Sequenced Gate
Operator Type (OT)
Set Handing (SH)
Usage Class (UC)
Bulk Charger State
Input Voltage VDC
BT <0>
STANDARD BATTERY
57
| www.hysecurity.com
Table 9. Viewing Operator Status Displays
Variables
Indicates whether the gate operator
was manufactured before (pre-2016)
or after UL 325 - 2016 Standard
of Safety changes that require
monitoring of external entrapment
sensors.
Software version and revision number
are hard-coded in Smart DC Controller.
PRIMARY or SECONDARY
(Display only appears when operator
is used in bi-parting gate systems.)
OT 12 = SwingSmart DC or DCS
LEFT or RIGHT
1, 2, 3, or 4
Three stages of charging:
z Bulk
z Absorption
z Float
The number varies depending on
the voltage that the power board is
providing.
0 = 8Ah (standard factory issue)
1 = 50Ah (optional upgrade)
2 = 110Ah (option)
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
DISPLAY AND MENU OPTIONS
All gate operators manufactured
in 2016 or later will show Build
Year - Post 2016 because it
contains software version h5.50
or later. If you plan to upload 5.50
software (or later) into your gate
operator, you will need to set the
appropriate build year according
to the date of manufacture.
Displays software version when you
press RESET or cycle power. You will
need software version when calling
Technical Support.
Indicates, in a dual gate setting,
whether operator is set to Primary
or Secondary. Setting is assigned in
Installer Menu.
Indicates and identifies the operator.
Designates which way a gate opens
viewed from operator. If it slides
left, it is a left-hand gate. Gate
handing is established in the initial
Setup Menu.
Displays operator's Usage Class
designation per UL 325 standards.
Indicates the state of charging
that the AGM battery is currently
handling.
Input voltage (DC Buss voltage)
to the Smart DC is shown. Helps
to determine proper power
connections.
Confirms operator's battery type. If
you use larger capacity batteries you
must configure operator through
Installer Menu. See BT - BATTERY
TYPE.
Description
MX3640-01 REV. D ©2018