INSTALLING THE LINKAGE ARMS

NOTICE
SwingSmart operators ship with separately
packaged linkage arms. The linkage arms have
a universal elbow joint and can be used on
either an operator with right handing or left-
handing by simply flipping the linkage arms.
Xg
Linkage Arms
B
A slight bend in the elbow joint can
minimize damage to the operator in
event of light gate strike.
NOTE: At secure sites, a straight
arm lowers the chance of someone
manually pushing the gate open.
NOTE: Maximum measurement for A = 38 inches (97cm)
Maximum measurement for B = 47.5 inches (121cm)
Figure 8. Installing Linkage Arms
31
| www.hysecurity.com
Hinge Center
X
Y
A
Operator Center
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
Table 3. Gate Linkage Arms Installation
Dimensions
Short Gate Installation:
For gates up to 10 feet (3 meters)
X
Y
10.5"
14"
(27cm)
(36cm)
18"
(46cm)
20"
(51cm)
Medium Gate Installation:
For gates up to 13 feet (4 meters)
X
Y
12"
22"
(31cm)
(56cm)
24"
(61cm)
28"
(71cm)
Long Gate Installation:
For gates up to 20 feet (6 meters)
X
Y
15"
30"
(38cm)
(76cm)
35"
(89cm)
40"
(101cm)
Custom Gate Installation:
X
Y
Space for custom
calculations:
INSTALLATION
Xg
A
23.5"
15.5"
(60cm)
(39cm)
27.5"
17.5"
(70cm)
(44cm)
29.5"
19"
(75cm)
(48cm)
Xg
A
33"
21"
(84cm)
(53cm)
35"
22"
(89cm)
(56cm)
39"
24"
(99cm)
(61cm)
Xg
A
44"
28"
(112cm)
(71cm)
49"
30.5"
(124cm)
(78cm)
(108cm)
54"
33.5"
(137cm)
(85cm)
(118cm)
Xg
A
X + Y - 1
0.63 * Xg
0.87 * Xg
MX3640-01 REV. D ©2018
B
21.5"
(55cm)
24.5"
(62cm)
26"
(66cm)
B
29"
(74cm)
30.5"
(78cm)
33.5"
(85cm)
B
38.5"
(98cm)
42.5"
46.5"
B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Swingsmart dcs20Swingsmart dc20