HySecurity SwingSmart DC Series Programming And Operations Manual page 119

Pad-mounted electromechanical swing gate operator with smart dc controller
Table of Contents

Advertisement

After programming the sensor inputs in the installer menu or during initial startup, the appropriate type
and number of sensors will need to be connected. Figure 75 below shows the wiring and dip switch
settings of an EMX-MON photo eye (typical thru-beam wiring). A retroreflective photo eye will be similar
and only have wiring simliar to the receiver of the thru-beam photo eye.
All external entrapment protection sensors must be
NC sensor outputs and wired to the SENSOR COM
terminal for monitoring and powering purposes.
The sensor becomes actively powered when the
gate operator's motor runs.
Jumper POWER INPUT
- 24V to COM in Receiver
DIP switches must be set as shown otherwise the photo eye will not operate correctly. If you receive an Alert,
"!ACTION BLOCKED" "Photo Eye Open" PEO or "Photo Eye Close" PEC, take steps to align the photo eye.
An Edge Sensor can be either hardwired through an adapter module (Hy2NC) or a wireless transmitter/
receiver combo (WEL-200 or iGAZE RE). Figure 76 below shows the wiring and dip switch settings of a
WEL-200. For more information and wiring diagrams of other recommended sensors see the "HySecurity
External Entrapment Sensor Wiring Guide".
EMX WEL-200 Wireless Edge Receiver
Dip Switch Settings determine which relay
activates when the associated edge is tripped.
119
| www.hysecurity.com
CAUTION
EMX IRB MON
Photo Eye
Receiver
CAUTION
Set DIP
Switches
1 = OFF
2 = OFF
3 = OFF
4 = ON
NOTE: DIP switches
mustbe set as shown
otherwise the photo
eye will not operate
correctly.
RED
BLACK
WHITE
CAUTION
Figure 75. EMX-MON Photo Eye Wiring
SENSOR COM
Figure 76. WEL-200 or iGAZE RE
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
CAUTION
Connect all contact and non-contact sensors to same power
source. Example, Do NOT connect photo eyes to +24VDC
and gate edges to +12VDC. Incompatible electricity flow. A
FAULT 2 will appear.
+24V
COMMON / NEG. to SENSOR COM
NC RELAY to SENSOR 1
+24V
SENSOR COM
SENSOR 1,2, or 3
REFERENCE
EMX IRB MON
Photo Eye
Transmitter
RED
+24V
BLACK
COMMON / NEG. to SENSOR COM
MX3640-01 REV. D ©2018

Advertisement

Table of Contents
loading

This manual is also suitable for:

Swingsmart dcs20Swingsmart dc20

Table of Contents