Reinstating Factory Defaults - HySecurity SwingSmart DC Series Programming And Operations Manual

Pad-mounted electromechanical swing gate operator with smart dc controller
Table of Contents

Advertisement

REINSTATING FACTORY DEFAULTS

Thirteen menu configurations are available in the
User Menu. Several other items in the Installer
Menu let you customize the operator depending
on the number of attached accessories and your
customer's needs.
CAUTION
Reinstating factory default clears ALL menu
settings stored in the operator and returns
them to factory defaults. It is recommended
that you save the menu settings before
reinstating factory defaults. You can write the
settings in a notebook or, if you have a laptop
computer, you can use HySecurity's START
software and download the menu settings and
save them to a file to upload to the operator
at a later date.
To reinstate factory defaults, take the following
steps and see Figure 47:
1. At a gate status display, press the MENU
button twice. This accesses the User Menu and
the CLOSE TIMER display appears.
2. Simultaneously, press the OPEN and RESET
buttons to enter the Installer Menu. Release
the buttons and the LEARN LIMITS display
appears. It is the first item in the Installer Menu.
3. Press NEXT until the FACTORY DEFAULTS
display appears. Factory default setting is 0.
4. Use the SELECT and NEXT buttons tonavigate
and change the number on the display to 1.
NOTICE
When you press SELECT to accept FD 1, the
factory settings are reinstated immediately
and the menu display returns to the initial
Setup Menu. The gate operator will not run
until the three menu parameters are entered:
Usage Class, Gate Handing, Gate Weight, and
Gate Length along with Sensor 1, 2, 3. Refer to
"Configuring the Setup Menu" on page 55.
82
| www.hysecurity.com
DISPLAY AND MENU OPTIONS
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
HYSECURITY
GATE CLOSED
OPEN
CLOSE
STOP
MENU
PREV
NEXT
SELECT
CT 0 (OFF)
CLOSE TIMER
OPEN
CLOSE
STOP
MENU
NEXT
SELECT
PREV
LL 0 (OFF)
LEARN LIMIT
OPEN
CLOSE
STOP
MENU
PREV
NEXT
SELECT
FD 1 (ON)
FACTORY DEFAULTS
OPEN
CLOSE
STOP
MENU
PREV
NEXT
SELECT
Figure 47. Reinstating Factory Defaults
1. Start at a gate
status display.
RESET
2. To access the
User Menu,
press the MENU
button twice.
RESET
3. Access the
Installer Menu, by
simultaneously,
pressing the
OPEN and
RESET
buttons.
RESET
4. Use NEXT to
navigate to the
menu display.
Change the
setting using the
SELECT and
RESET
NEXT buttons.
MX3640-01 REV. D ©2018

Advertisement

Table of Contents
loading

This manual is also suitable for:

Swingsmart dcs20Swingsmart dc20

Table of Contents