Table 15. User-Programmable User Relays - Function Options
No.
Name
Safety Mode Alert
9
output
Entrapment Mode
10
Alert output
Unauthorized Vehicle
11
Entry output
Outside Obstruction
12
Vehicle Detector
output
13 Loitering Alert
Gate nearing full travel
14
output
15 Gate Failure output
16 Motor Running output
AC Power Failure
17
output
DC Power Failure
18
output
19 Flasher Relay
Free Exit Loop Vehicle
20
Detector output
Inside Obstruction
21
Vehicle Detector
output
Center Loop Detector
22
output
95
| www.hysecurity.com
Activated when system is in Safety Mode or Entrapment Mode. Safety
Mode occurs upon an impact with an obstruction. Entrapment Mode
means gate is stopped and occurs if inherent entrapment sensor triggers
while system is in Safety Mode.
Activated only when system is in Entrapment Mode.
Activated when a second vehicle enters from outside without a valid
input from an access control device. The OOLD and IOLD loops must
be capable of being triggered at the same time for this relay to ever
activate. This output releases when an access control input signals open
or gate reaches the close limit position.
This output is active whenever Outside Obstruction Loop Detector is
tripped. Interlocks an entry device to prevent pedestrian use.
Indicates vehicle is loitering on Outside Obstruction Loop with the gate
closed. Adjustable from a 0 second to 135 second delay in 15-second
intervals.
NOTE: LT - LOITERING ALERT adjustments can be made in Installer
Menu
Activated when gate is approaching full open or full closed. Relay
activates three feet from where software expects limit switch to be
triggered whether moving toward full open, full close, or in a reverse
travel mode.
Activated to report occurence of problem. Indicates the system is in
an Error, Fault, Alert, or Entrapment Mode. If active, gate is disabled.
Active when motor is running and gate is in motion.
This relay is normally energized and drops with loss of AC power.
Activated when battery power is very low, but output ceases when
battery is dead (18 volts). Relay is triggered when battery is less than
21 volts.
Controls flashing lights to pulse once per second. Relay is constantly
pulsing except when open limit switch is triggered. Recommended to
use User Relay 2 since it is an electronic switch
Active whenever Exit Loop is tripped.
Active whenever Inside Obstruction Vehicle Detector is tripped
Active whenever Center (Shadow) loop detector is tripped.
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
VEHICLE DETECTOR
Description
MX3640-01 REV. D ©2018