HySecurity SwingSmart DC Series Programming And Operations Manual page 72

Pad-mounted electromechanical swing gate operator with smart dc controller
Table of Contents

Advertisement

User Menu
Display
RT 0 (30 SECS)
MAXIMUM RUN
TIMER
PO (OFF)
Partial Open
EC 0 STOP ONLY
Eye Close Logic
EO 0 (STOP ONLY)
EYE OPEN LOGIC
GC 0 NO CONTACT
Gate Edge Output
GR 0 (FULL OPEN)
GATE EDGE LOGIC
SR 1 REVERSE 2S
IES Sensor Logic
72
| www.hysecurity.com
Table 12. Smart DC Controller - Installer Menu Functions
Setting Options
(Bold = Factory
Settings)
0 = 30 Seconds
max run,
1 = 300 Seconds
max run
0 = OFF
7 = 7 ft, 8 = 8ft,
through 32 = 32 ft
0 = Close eye
stops only
1 = 2s reverse to
open
2 = Full Open
0 = Open eye
stops only
1 = 2s reverse to
close
0 = Normally Open
Edge
1 = Normally Closed
0 = Edge reverses
full open
1 = 2s reversal only
0 = IES reverses full
open
1 = 2 second
reversal only
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
DISPLAY AND MENU OPTIONS
Menu Tasks and Explanations
Assigns a motor run time of 30 or 300
seconds. If the gate opening or closure
takes longer than 30 seconds, you'll
need to set the run timer to 1.
Sets distance (from closed gate position)
where gate stops if the partial open
input is activated.When a number is
entered in PO display, open partial input
becomes operational. Only available on
slide gate operators.
Default setting is non-reversal if close
photo eye is triggered while closing.
A setting of 1 causes gate to reverse
toward open for two seconds if triggered
while closing. A setting of 2 reverses the
gate to full open.
Default setting is non-reversal if open
photo eye is triggered while opening. A
setting of 1 causes gate to reverse travel
and close for two seconds if triggered
while opening.
This menu item only appears when UC
is set to 4. Default setting is edge sensor
with Normally Closed (NC) output.
Optional setting of 0 requires an (NO)
output.
Default setting is a full-open reversal if
gate edge is triggered while closing.
Optional setting of 1 causes gate to
reverse for two seconds if triggered
while closing.
Default setting is a two-second duration
reversal if inherent sensor is triggered.
Optional setting of 0 will cause gate to
reopen fully if triggered while closing.
Associated
DC Controller
Display
Connections
(N/A)
OPEN
PARTIAL
COM
Sensor
Common
Sensor Input
Sensor
Common
Sensor Input
Sensor
Common
Sensor Input
Sensor
Common
Sensor Input
(N/A)