SMART TOUCH ANALYZE AND RETRIEVE
TOOL
HySecurity provides Smart Touch Analyze and
Retrieve Tool (START) software to help HySecurity
gate operator users and installers conduct the
following field service activities:
z Configure installer and user menu settings
z View the operator history (event) log
z Display monitored inputs for operator
diagnostics
z Load Smart DC Controller (SDC) operator code
With START software loaded on your laptop
computer, you have an invaluable management
tool for all HySecurity operators. Either the USB
port or the RS-232 serial port, found on the Smart
DC Controller (see Figure 59), allows you to
download system diagnostics and upload system
configurations using the START software. The
free START software is conveniently located on
the www.hysecurity.com website. Instructions for
downloading START are found on the website,
as well.

What You Need

z Standard USB 2.0 A-B communications cable.
If you are using the HySecurity RS-232 to USB
adapter, be sure to install the USB driver in your
laptop.
z Laptop computer with Windows PC operating
system (XP, Vista, or Windows 7/8/8.1/10)
z Minimum 128MB of RAM
z Minimum 5MB of hard drive disk space
z VGA graphics card (minimum resolution of 800
x 600)

Installing START Software

Read the START User Manual, and then take the
following steps to download START software:
1. Bring up your web browser and type in http://
www.hysecurity.com in the command line.
2. Click Technical Support (left column) on the
HySecurity home page.
102
| www.hysecurity.com
3. Enter your user name and password. If you do
4. Click to Download: S.T.A.R.T. software for
5. Read the End User License Agreement and,
6. Click RUN. A setup window appears.
7. Follow the step-by-step instructions to
8. When the download is complete, log out of the
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL

GENERAL MAINTENANCE

not have a user name, register as an online
member.
Smart Touch and Smart DC.
if you agree to the terms, click on, I accept
(bottom of the page).
NOTICE
If the operating system on your laptop is
VISTA or Windows 7, you must first disable the
"User Account Control Settings," refer to the
procedure in "Setting User Account Controls"
on page 103 and then continue to step 9.
complete the installation.
HySecurity website. Shortcuts for the START
and Smart DC Controller History Logs appear
on your laptop's desktop.
USB
Power Connector
POWER
DRIVE
1
STOP BUTTON
2
OPEN BUTTON
3
CLOSE BUTTON
REMOTE OPEN AND
4
RADIO CONTROL
5
OPEN/CLOSE
6
OPEN PARTIAL
INTERLOCK OPEN
7
TIME CLOCK OPEN
8
FREE EXIT DETECTOR
DISABLE EXIT DETECTOR
9
DISABLE CLOSE TIMER
10
INSIDE OBSTRUCTION
VEHICLE DETECTOR
OUTSIDE OBSTRUCTION
11
VEHICLE DETECTOR
12
SHADOW/RESET
VEHICLE DETECTOR
EDGE SENSOR
14
PHOTO EYE POWER
24 VOLTS COMMON
15
PHOTO EYE POWER
16
DO NOT USE
PHOTO EYE
17
OPEN DIRECTION
18
DO NOT USE
19
PHOTO EYE
CLOSE DIRECTION
20
DO NOT USE
CHARGER
21
AC LOSS
22
LOCK INTERLOCK
23
EMERG CLOSE
24
FIRE DEPT OPEN
Smart Touch Controller
LED
LIMIT
DUAL GATE
RPM
COM
A
B
COM
Figure 59. RS-232 and USB Connection
RS-485
COMMUNICATION
RS485
COM
NO
STATUS
HySecurity
MX000585
VERSION
S/N
Connect to RS-232 with
a HySecurity adapter.
RADIO OPTIONS
OPEN
+24V
+24V
EDGE
COM
MX3640-01 REV. D ©2018