HySecurity SwingSmart DC Series Programming And Operations Manual page 73

Pad-mounted electromechanical swing gate operator with smart dc controller
Table of Contents

Advertisement

User Menu
Display
PC 1 NO CONTACT
PHOTO EYE
OUTPUT
GC 0 NO CONTACT
GATE EYE OUTPUT
S1 0
Sensor #1 Type
S2 0
Sensor #2 Type
S3 0
Sensor #3 Type
DT 0 FREE EXIT
DISABLE FUNCTION
73
| www.hysecurity.com
Table 12. Smart DC Controller - Installer Menu Functions
Setting Options
(Bold = Factory
Settings)
0 = Normally Open
PE output
1 = Normally
Closed
(supervised)
0 = Normally
Open Edge
1 = Normally
Closed
0 - disabled
1 - (NOT USED)
2 - (EYE CLOSE)
3 - (EDGE CLOSE
4 - (EYE OPEN)
5 - (EDGE OPEN)
6 - (EDGE BOTH)
7 - (EYE BOTH)
Same as Sensor 1
Same as Sensor 1
0 = Disable Free
Exit
1 = Disable Close
Timer
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
DISPLAY AND MENU OPTIONS
Menu Tasks and Explanations
This menu item only appears when UC
is set to 4. Default setting is photo eyes
with Normally Close outputs. Optional
setting 0 requires a Normally Open (NO)
output. When set for NC, connection is
monitored and any short circuit fault will
generate a FAULT 2 alert which requires
a STOP or RESET button press to re-
enable gate operation.
This menu item only appears when UC
is set to 4. Default setting is edge sensor
with Normally Closed (NC) output.
Optional setting of 0 requires an (NO)
output.
UL 325 - 2018 sensor input setting for
external entrapment protection sensor
monitoring. All three sensor types must
be configured to a non-zero number
before the gate operator will move the
gate. Edge Both is only available in
Swing Gate operator types. Eye Both
is only available in Slide Gate operator
types.
Same as Sensor 1
Same as Sensor 1
Configures BLOCK EXIT input to
disable either Free Exit Detector
function or, alternately, Close Timer
function. Default setting disables free
exit detector.
NOTE: Free exit is disabled when
gate is at its closed limit. If closed limit
is not tripped, free exit continues to
work normally.
Associated
DC Controller
Display
Connections
Photo eye
connections:
Sensor
Common
Sensor Input
+24V
S e n s o r
Common
Sensor Input
BLOCK EXIT
COM
MX3640-01 REV. D ©2018

Advertisement

Table of Contents
loading

This manual is also suitable for:

Swingsmart dcs20Swingsmart dc20

Table of Contents