HySecurity SwingSmart DC Series Programming And Operations Manual page 20

Pad-mounted electromechanical swing gate operator with smart dc controller
Table of Contents

Advertisement

Example wiring diagrams are shown below for a non-contact sensor (photo eye) and a contact sensor
(wireless edge sensor).
All external entrapment protection sensors must be
NC sensor outputs and wired to the SENSOR COM
terminal for monitoring and powering purposes.
The sensor becomes actively powered when the
gate operator's motor runs.
Set DIP
Switches
1 = OFF
2 = OFF
3 = OFF
4 = ON
NOTE: DIP switches
mustbe set as shown
otherwise the photo
eye will not operate
correctly.
Jumper POWER INPUT
- 24V to COM in Receiver
DIP switches must be set as shown otherwise the photo eye will not operate correctly. If you receive an Alert,
"!ACTION BLOCKED" "Photo Eye Open" PEO or "Photo Eye Close" PEC, take steps to align the photo eye.
EMX WEL-200 Wireless Edge Receiver
Dip Switch Settings determine which relay
activates when the associated edge is tripped.
20
| www.hysecurity.com
CAUTION
EMX IRB MON
Photo Eye
Receiver
CAUTION
RED
BLACK
WHITE
CAUTION
Figure 1. EMX-MON Photo Eye Wiring
SENSOR COM
Figure 2. WEL-200 or iGAZE RE
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
CAUTION
Connect all contact and non-contact sensors to same power
source. Example, Do NOT connect photo eyes to +24VDC
and gate edges to +12VDC. Incompatible electricity flow. A
FAULT 2 will appear.
+24V
COMMON / NEG. to SENSOR COM
NC RELAY to SENSOR 1
+24V
SENSOR COM
SENSOR 1,2, or 3
SAFETY INFORMATION
EMX IRB MON
Photo Eye
Transmitter
RED
+24V
BLACK
COMMON / NEG. to SENSOR COM
MX3640-01 REV. D ©2018