HySecurity SwingSmart DC Series Programming And Operations Manual page 127

Pad-mounted electromechanical swing gate operator with smart dc controller
Table of Contents

Advertisement

Display
Condition
ALERT 6 LIM
NOT RELEASED
ALERT 7
FREQ SHIFT
FAULT
ALERT 8
LOOP SHORTED
ALERT 9
LOOP OPEN
ALERT 10
12C BUS ERROR
127
| www.hysecurity.com
Table 22. Smart DC Controller - Troubleshooting
Description
Alert, Error or
Fault
The limit did not
release when
z Broken drive belt.
the operator was
z Hardware holding the arm.
commanded to
move.
Likely causes are poor integrity of
H Y - 5 B
h a s
loops or metallic objects within range.
d e t e c t e d
a
This message will also indicate which
frequency change
detector alert applies to: Exit Loop
outside normal
(ELD), Inside Obstruction Loop (IOLD),
range.
Outside Obstruction Loop (OOLD), or
Center Loop (CLD) - (User Relay 22).
H Y - 5 B
h a s
d e t e c t e d
a
Caused by inadequate insulation of
loopshorted to
loop wires.
ground.
H Y - 5 B
h a s
detected a lack
Caused by broken loop wire or wire
of continuity in
has come unplugged from detector.
loop wire.
Smart DC
Caused by removal of HY-5B or lack
Controller has
of integrity of socket connection.
detected a
This message will also indicate which
communication
detector alert applies to: Exit Loop
error with a
(ELD), Inside Obstruction Loop (IOLD),
HY-5B vehicle
Outside Obstruction Loop (OOLD), or
detector.
Center Loop (CLD) - (User Relay 22).
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
Possible Causes
REFERENCE
Solutions
z Tighten taper clamp
(SwingSmart DC)
z Check/replace drive
belt.
z Remove debris from
limit area
z Check limit switches
and replace as
required
z Check limit plate
z Release any holds
on the arm.
z Relearn Limits.
(StrongArmPark DC
and WedgeSmart
DC)
Loop lead in wires and
roadway should be
checked for problems
or replaced.
Loop lead in wires and
roadway should be
checked for problems
or replaced.
Loop and lead in wires
should be checked for
problems or replaced.
Remove and re-install
the HY-5B and press
RESET. Replace HY-5B,
if necessary.
MX3640-01 REV. D ©2018