User Menu
Display
LT 3 (75 SECS)
LOITERING ALERT
SA 0 (OFF)
SDC Address
ELD0 RUN MODE
Exit Loop Set
ILD 0 (RUN MODE)
IN OBS LOOP SET
OLD 0 (RUN MODE)
OUT OBS LOOP SET
76
| www.hysecurity.com
Table 12. Smart DC Controller - Installer Menu Functions
Setting Options
(Bold = Factory
Settings)
0 = 0s delay
1 = 15s
2 = 45s
3 = 75 second
delay
4 = 105s
5 = 135s
0 = No network
1 to 99 Network
"drop" address
0 = Run mode
1 = Show frequency
2 = Show call level
0-7
3 = Set Frequency
0 = Run mode
1 = Show frequency
2 = Show call level
0-7
3 = Set Frequency
0 = Run mode
1 = Show frequency
2 = Show call level
0-7
3 = Set Frequency
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
DISPLAY AND MENU OPTIONS
Menu Tasks and Explanations
This function monitors activation
of Outside Obstruction Loop when
the gate is closed and not running.
When adjustable period of time is
exceeded, User Relay No. 13 triggers
and reports loitering in diagnostics log.
Adjust time delay before activating
user relay.Maximum time setting is
135 seconds. See "Figure 68. Setting
the User Relay Function in the Installer
Menu" on page 110.
NOTE: This menu controls a user relay
set to Function No. 13
Set system address for network
communication:
0 = no network communication
1 - 99 sets individual polling
addresses. Use addresses 1-4 when
connecting to HyNet.
Controls HY-5A or HY-5B Free Exit
detector. If an HY-5B is used, additional
settings of 4-8 are available.
Controls HY-5A or HY-5B Inside
Obstruction Loop detector. If an HY-5B
is used, additional settings of 4-8 are
available.
Controls HY-5A or HY-5B Outside
Obstruction Loop detector. If an HY-5B
is used, additional settings of 4-8 are
available.
Associated
DC Controller
Display
Connections
User relays
RS-485
HY-5B
HY-5B
HY-5B