HySecurity SwingSmart DC Series Programming And Operations Manual page 71

Pad-mounted electromechanical swing gate operator with smart dc controller
Table of Contents

Advertisement

User Menu
Display
FO 0 (OFF)
Fire Dept Open
SE 2
IES Sensitivity
SS 0 (OFF)
IES STOP ONLY
LC 0 (0.0 SECS)
Leaf Delay Close
LO 0 (0.0 SECS)
Leaf Delay Open
71
| www.hysecurity.com
Table 12. Smart DC Controller - Installer Menu Functions
Setting Options
(Bold = Factory
Settings)
0 = disabled
1 = enabled
0 = maximum
sensitivity
2 = default
Setting
9 = least sensitivity
0 = stop, reverse
for 2s
1 = stop only
0 = no delay
1 through 20 in ½
second increments
For example:
1 = ½ second
10 = 5 seconds
20 = 10 seconds
0 = no delay
1 through 20 in ½
second increments
For example:
1 = ½ second
10 = 5 seconds
20 = 10 seconds
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
DISPLAY AND MENU OPTIONS
Menu Tasks and Explanations
Enables Fire Department Open input.
When set to 1, signal received through
this input overrides all photoelectric
eyes and edge sensors and opens gate.
Pressing RESET button (or the OPEN
push button) is required before gate
can be closed.
Adjusts sensitivity of internal inherent
entrapment sensor (IES). Available
settings are 0 to 9 with 9 being
least sensitive. HySecurity strongly
recommends that you avoid setting IES
sensitivity higher than 6.
NOTE: Before changing IES sensitivity,
make sure that gate rolls smoothly
without obstruction. Fix any issues with
gate hardware.
In a Usage Class 4 environment,
operator can be set to stop gate and
not reverse gate travel after an IES
trip.
Only appears if gate operator is set up
as a Primary or a Secondary. Available
settings are 1 through 20. Each
increment adds ½ second time delay
following a command to close before
operator begins closing. Provides up
to a 10 second time delay.
Only appears if gate operator is set up
as a Primary or a Secondary. Available
settings are 1 through 20. Each increment
adds ½ second time delay following a
command to open before operator
activates. Provides up to a 10 second
time delay.
Associated
DC Controller
Display
Connections
+24V DC
EMERG OPEN
See Note.
(N/A)
DUAL GATE
inputs on both
operators
DUAL GATE
inputs on both
operators
MX3640-01 REV. D ©2018