HySecurity SwingSmart DC Series Programming And Operations Manual page 74

Pad-mounted electromechanical swing gate operator with smart dc controller
Table of Contents

Advertisement

User Menu
Display
OR 1 REVERSE
OUTSIDE OBS LOOP
IR 1 REVERSE
INSIDE OBS LOOP
HD 1 HOLD OPEN
CENTER LOOP
HOLD
DL 1 STANDARD
Detector Logic
74
| www.hysecurity.com
Table 12. Smart DC Controller - Installer Menu Functions
Setting Options
(Bold = Factory
Settings)
0 = Pause closing
only
1 = Enable reverse
to open
0 = Pause closing
only
1 = Enable
reversing to open
0 = Hold open only
1 = Hold close and
hold open
1 = Standard
2 = Quick closed
3 = Forced Time out
4 = Full anti-tailgate
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
DISPLAY AND MENU OPTIONS
Menu Tasks and Explanations
Default is for full reversal when
Outside Obstruction Loop is triggered
while closing. A setting of 0 causes
gate to only pause when triggered.
Gate closure ontinues as soon as loop
is clear again.
Default is for full reversal when Inside
Obstruction Loop is triggered while
closing. A setting of 0 causes gate to
only pause when triggered. Closure
begins as soon as loop is clear again.
Configures the function of the Center
Loop (Shadow Loop) when triggered:
Setting 1 - prevents opening and closing
of the gate when the Center Loop is
tripped if the gate is on either (opened
or closed) limit switches.
Setting 0 - prevents closing when on the
open limit switch.
This selection determines whether
close timer begins to count down after
vehicles have departed detector loops
or whether close timer will count down
while the loops are occupied. Gate can
only close when all loop detectors are
clear.
Default settings causes Close Timer to
start when all loops are clear. A setting of
2 causes Close Timer to start when open
limit is reached. A setting of 3 forces
the Close Timer to 0 when the OOLD
and IOLD are tripped simultaneously. A
setting of 4 stops the gate when OOLD
and IOLD are tripped simultaneously
and closes from that point when the
loops clear.
Associated
DC Controller
Display
Connections
OUTSIDE OBS
LOOP COM or
HY-5B
INSIDE OBS
LOOP COM
or HY-5B
CENTER
LOOP
COM
HY-5B
MX3640-01 REV. D ©2018

Advertisement

Table of Contents
loading

This manual is also suitable for:

Swingsmart dcs20Swingsmart dc20

Table of Contents