SimonsVoss
Manual
SmartRelais 3 Advanced
5.3 SmartOutput module
Circuit
No.
Explanation
board
4
+
V
GND. Connection for external power supply. Connected
5
-
electrically to 3.
1
2
3
4
5
6
28
27
26
25
24
23
22
Circuit
No.
Explanation
board
Brownout detection: Open collector, connected to GND
if supply voltage is sufficient.
This output activates if the supply voltage at V
low 10.0 V
connected to the AUX relay's coil. If the supply voltage
1
Out
falls at V
lay contacts activate unchecked due to the decreasing
voltage. When the supply voltage is applied, the output
does not activate until the module has fully initialised
and relay contacts can no longer switch unchecked.
2
I-
Isolated digital input. Currently not in use.
3
I+
Isolated digital input. Currently not in use.
Controller connection: Data Line B; connected to con-
4
B
tact for Reader 3.
. Connection for external power supply.
IN
7
8
9
10 11 12 13 14
21
20
19
18
17
16
(±0.5 V
DC
DC
, the AUX relay activates before the other re-
IN
5 | Connections
15
). The earth connection is usually
16 / 135
falls be-
IN
Need help?