Event Logging Of Unauthorised Accesses; Flip-Flop - Simons Voss Technologies SmartRelais 3 Advanced Manual

Hide thumbs Also See for SmartRelais 3 Advanced:
Table of Contents

Advertisement

SimonsVoss
Manual
SmartRelais 3 Advanced
Programming the con-
troller

8.2.3 Event logging of unauthorised accesses

8.3 Flip-flop

ATTENTION
IMPORTANT
4. Press on OK to accept query.
ð Access list is now deleted.
Resetting the controller results in a programming requirement.
Execute programming for the controller (see Programming [} 24]).
Only authorised accesses are logged in storage mode. There is an option
to log unauthorised access attempts too.
ü LSM 3.4 or higher installed.
ü Components wired correctly (see wiring [} 55]).
ü Components connected to power.
1. Double-click on the SmartRelay 3 entry in the matrix to open the
settings.
2. Change to the [Configuration/Data] tab.
3. Enable the
Log unauthorised attempts checkbox.
4. Click on the Apply button.
5. Click on the Exit button.
6. Execute programming (see Programming [} 24]).
ð Unauthorised access attempts are now also logged.
The switching time for the relay in the controller can be freely programmed
between 0 s and 25 s. If the controller relay needs to be permanently
operated, you can activate flip-flop mode.
Changing over the relay contact if power fails
The relays in the controller are not bi-stable. Consequently, permanent
power is required for switched mode. Relays are no longer supplied with
electricity if there is a power outage. In such cases, they switch to a power-
off state even without using an identification medium, depending on the ori-
ginal position.
1. Connect external components in such a way that a power-off state
poses no risks.
The flip-flop option is not available if the SREL3 ADV system is used with
SmartOutput modules.
ü LSM 3.4 SP1 or higher installed.
ü Components connected to power.
ü Components wired correctly (see wiring [} 55]).
8 | SREL3 ADV in LSM
84 / 135

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SmartRelais 3 Advanced and is the answer not in the manual?

Questions and answers

Table of Contents