Remote Opening - Simons Voss Technologies SmartRelais 3 Advanced Manual

Hide thumbs Also See for SmartRelais 3 Advanced:
Table of Contents

Advertisement

SimonsVoss
Manual
SmartRelais 3 Advanced
Locking in the non-authorised time period (open relay contacts)
Locking automatically
always
Not possible

8.12 Remote opening

IMPORTANT
Remote opening with
USB cable
only if locked
– Controller: Opens
relay contacts
(locked) as soon
as authorisation
ends in the time
zone plan.
Identification
media close relay
contacts for
configured pulse
duration for the
remaining
authorised time
period.
– SmartOutput
module: Opens
relay contacts
(locked) as soon
as authorisation
ends in the time
zone plan.
Identification
media close relay
contacts for
configured pulse
duration for the
remaining
authorised time
period.
You can also use LSM to operate the relay in the controller without
identification media at any time.
A remote opening takes precedence over time zone control. It also oper-
ates the relay if the relay contacts should remain open after time zone con-
trol.
ü Controller has already been programmed.
ü Components wired correctly (see wiring [} 55]).
ü Components connected to power.
1. Use | Network | to select the Lock activation item.
8 | SREL3 ADV in LSM
Locking manually
Not possible