Signal Settings - Simons Voss Technologies SmartRelais 3 Advanced Manual

Hide thumbs Also See for SmartRelais 3 Advanced:
Table of Contents

Advertisement

SimonsVoss
Manual
SmartRelais 3 Advanced

8.6 Signal settings

– Block feedback signals are transmitted from the identification media to
the controller. The physical access list is also transmitted to the
controller in the case of cards. All information is buffered in the
controller. Once connection is re-established, the controller transmits
the stored information to LSM.
– Authorisation changes are not edited in the virtual network.
– Input events are not transmitted to the database and expire.
In some cases, an optical or audible feedback signal may not be wanted.
You can also change signal settings as you wish.
ü LSM 3.4 or higher installed.
ü Controller has already been programmed.
ü Components wired correctly (see wiring [} 55]).
ü Components connected to power.
1. Double-click on the SmartRelay 3 entry in the matrix to open the
settings.
2. Change to the [Configuration/Data] tab.
3. Click on the Extended configuration button.
ð The "Extended configuration" window will open.
4. Enable or disable the
5. Enable or disable the
6. Click on the OK button.
8 | SREL3 ADV in LSM
Turn off LED checkbox.
Turn off beeper checkbox.
87 / 135

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SmartRelais 3 Advanced and is the answer not in the manual?

Questions and answers

Table of Contents