6.3.2.2 Resetting controller over the network
4. Select the "USB link to the TCP nodes" item.
5. Click on the Read button.
ð Locking device is read.
ð The "G2 Smart Relay 3" window will open.
6. Click on the Reset button.
ð The "Reset lock" window will open.
7. Enter the locking system password or apply it from the database.
8. Click on the Reset button.
ð Locking device is reset.
ð Locking device reset.
Alternatively, the controller can also be reset over the network after initial
programming. This option is ideal if the controller has already been installed
and cannot be reached physically.
ü Components wired correctly (see wiring [} 55]).
ü Components connected to power.
ü Controller has already been programmed.
ü Controller connected to computer via network.
1. Mark the entry on the SmartRelay 3 controller in the matrix.
2. Use | Programming | to select the Read highlighted locking device/set
time item.