SimonsVoss
Manual
SmartRelais 3 Advanced
IMPORTANT
6.2.1 Establishing IP settings
6.2.2 Creating a communication node
IMPORTANT
Click on the Ping button to check whether the service is running and re-
sponding. If the service responds, you can continue. If it does not, try to
launch the service again.
24. Click on the Transmit button in LSM.
ð Controller can be reached via network.
25. Terminate the SimonsVoss VNHost Server und SimonsVoss
CommNode Server services.
26. Set up your backup again (see LSM manual).
27. Launch the SimonsVoss VNHost Server and SimonsVoss CommNode
Server services again.
ð Controller can be reached via network and flashes blue.
The SREL3 ADV system controller needs a static IPv4 address to operate
in the network. Ask your IT Department or your network administrator to
assign you a free static IPv4 address and provide you with the following
information:
– IPv4 address
– Associated subnet mask
– Default gateway (only if not all LSM or System 3060 devices are in the
same network)
Alternatively, you can also use DHCP with LSM Version 3.4 SP1 and
above. To do so you need to open the [IP settings] tab and enable the
DHCP activated checkbox.
ü LSM launched.
1. Use | Network | to select the Communication nodes item.
2. Enter the communication node name (freely selectable;
recommended: VN host or CommNode).
3. Enter the host name of the computer on which SimonsVoss VNHost
Server has been installed.
You can verify the host name as follows:
1. Press the Windows key.
2. Enter cmd.
3. Press the Enter key to confirm.
ð The "[offen]" window will open.
6 | Setting up
23 / 135
Need help?
Do you have a question about the SmartRelais 3 Advanced and is the answer not in the manual?
Questions and answers