SimonsVoss
Manual
SmartRelais 3 Advanced
8.11.2 Extended configuration with SmartOutput modules
Unlocking in the authorised time period (close relay contacts)
Unlocking automatically
always
Not possible
only if locked
– Controller: Closes
relay contacts
(unlocked) as soon
as authorisation
starts in the time
zone plan. No
influence by
identification
media within the
authorised time
period.
– SmartOutput
module: Closes
relay contacts
(unlocked) as soon
as authorisation
starts in the time
zone plan. No
influence by
identification
media within the
authorised time
period.
8 | SREL3 ADV in LSM
Unlocking manually
always
Not possible
only if locked
– Controller: Closes
relay contacts
(unlocked) as soon
as identification
medium is
activated after
authorisation starts
within the time
period. No
influence by
identification
media for the rest
of the authorised
time period after
that.
– SmartOutput
module: Closes
relay contacts
(unlocked) as soon
as authorisation
starts in the time
zone plan. No
influence by
identification
media for the rest
of the authorised
time period.
94 / 135