Appendix A: Pri Gateway Alarms - Avaya Communication Server 1000 Installation And Commissioning Manual

Hide thumbs Also See for Communication Server 1000:
Table of Contents

Advertisement

Appendix A: PRI Gateway alarms

The alarms as shown in
commands, and on the product LEDs.
Table 39: PRI Gateway alarms
Level 1
Alarm type (receive side)
BPV
FE (Ber)
CRC4 errors
FEBE
Slip
Level 2
AIS
RAI (ts0)
Los
LFAS
CLMAS
Level 1
BPV
FE (Ber)
ESF CRC6 errors
ESF - FEBE
Slip
Level 2
AIS
SF – Digit 2 yellow alarm
ESF – FDL,(D2) yellow alarm
Los
LFAS
ESF – CLMAS
Media Gateway 1000E PRI Gateway Installation and Commissioning
Table 39: PRI Gateway alarms
E1, European ISDN Alarms
Description
Bipolar violation
Frame alignment errors (bit error rate)
CRC4 errors
CRC4 errors reported by remote side
All one
Remote alarm indication
Loss of signal
Lost frame alignment signal
Lost of CRC4 frame alignment signal
T1 ISDN SF and ESF
Bipolar violation
Frame alignment errors (bit error rate)
CRC6 errors
CRC6 errors reported by remote side
All one
Yellow alarm
Yellow alarm
Loss of signal
Lost frame alignment signal
Loss of CRC6 frame alignment signal
on page 147 appear in LD 60, CLI status
March 2013
147

Advertisement

Table of Contents
loading

This manual is also suitable for:

Media gateway 1000e priMg 1000e pri

Table of Contents