CO Demand Diagnostic Test (#3)

For ground start trunks, port media module relays are operated and checks are made to see if
the port can detect and apply ground on the Tip lead. This test also verifies that there is no
external ground on the Ring lead. In the absence of other failures, the media module should be
replaced only if this test fails with the CO line disconnected.
This test also checks the on-board programmable transmission circuits that allow the media
module to support transmission characteristics of several different countries.
Table 49: TEST #3 CO Demand Diagnostic Test
Error
Test
Code
Result
ABORT
1000
ABORT
1004
ABORT
1005
ABORT
1018
ABORT
2000
ABORT
Description/ Recommendation
Could not allocate system resources to run this test.
Retry the command at 1-minute intervals for a maximum of 5 times.
System resources required to run this test are not available. The port
may be busy with a valid call.
Use the display port GGGVSpp command to determine the trunk group/
member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests. You must
wait until the port is idle before retesting.
If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
The port was seized by a user for a valid call.
Use the display port GGGVSpp command to determine the trunk group/
member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests. You must
wait until the port is idle before retesting.
If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
Test inapplicable to present configuration. This is a normal condition.
Test has been disabled via administration.
For this test to run, the Maintenance Tests? field on the trunk group
form must be set to n. The form is accessed with the change trunk-group
grp# command.
Response to the test was not received within the allowable time period.
Retry the command at 1-minute intervals for a maximum of 5 times.
CO-TRK (Analog CO Trunk)