Selection; Electrical Data, 380-500 - Danfoss VLT AutomationDrive FC 300 Design Manual

90-1200 kw
Hide thumbs Also See for VLT AutomationDrive FC 300:
Table of Contents

Advertisement

Selection

4 Selection
4.1 Electrical Data, 380-500 V
FC 302
High/Normal load*
4
4
Typical shaft output at 400 V [kW]
Typical shaft output at 460 V [hp]
Typical shaft ouptut at 500 V [kW]
Enclosure IP21
Enclosure IP54
Enclosure IP20
Output current
Continuous (at 400 V) [A]
Intermittent (60 s overload)
(at 400 V)[A]
Continuous (at 460/500 V) [A]
Intermittent (60 s overload)
(at 460/500 V) [kVA]
Continuous kVA (at 400 V) [kVA]
Continuous kVA (at 460 V) [kVA]
Continuous kVA (at 500 V) [kVA]
Maximum input current
Continuous (at 400 V) [A]
Continuous (at 460/500 V) [A]
Max. cable size: mains, motor, brake
and load share [mm
Max. external mains fuses [A]
Estimated power loss at 400 V [W]
Estimated power loss at 460 V [W]
Weight, enclosure IP21, IP54 kg (lbs.)
Weight, enclosure IP20 kg (lbs.)
5)
Efficiency
Output frequency
Heatsink overtemp trip
Control card ambient trip
*High overload=150% current for 60 s, Normal overload=110% current for 60 s
Table 4.1 Technical Specifications, D-frame 380-500 V Mains Supply 3x380-500 V AC
1) American Wire Gauge.
2) Wiring terminals on N132, N160, and N315 frequency converters cannot receive cables one size larger.
3) For fuse ratings, see 7.2.1 Fuses.
4) Typical power loss is at normal conditions and expected to be within
values are based on a typical motor efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the frequency converter. If the
switching frequency is raised from nominal, the power losses rise significantly. LCP and typical control card power consumptions are included.
Options and customer load can add up to 30 W to the losses, though usually a fully loaded control card and options for slots A and B each add
only 4 W.
5) Measured using 5 m screened motor cables at rated load and rated frequency.
6) Additional frame size weights are as follows: D5h - 166 (255) / D6h - 129 (285) / D7h - 200 (440) / D8h - 225 (496). Weights are in kg (lbs).
56
VLT
N90K
HO
NO
90
110
125
150
110
132
D1h
D1h
D3h
177
212
266
233
160
190
240
209
123
147
127
151
139
165
171
204
154
183
2
(AWG)]
1)2)
3
315
4) 5)
2031
2559
4) 5)
1828
2261
6)
6)
®
AutomationDrive FC 300 Design Guide 90-1200 kW
N110
N132
HO
NO
HO
NO
110
132
132
160
150
200
200
250
132
160
160
200
D1h
D1h
D1h
D1h
D3h
D3h
212
260
260
315
318
286
390
347
190
240
240
302
285
264
360
332
147
180
180
218
151
191
191
241
165
208
208
262
204
251
251
304
183
231
231
291
2x95 (2x3/0)
350
400
2289
2954
2923
3770
2051
2724
2089
3628
62 (135)
62 (135)
0-590 Hz
75 °C
± 15% (tolerance relates to variety in voltage and cable conditions.) These
MG34S202 - Rev. 2013-08-19
N160
N200
HO
NO
HO
NO
160
200
200
250
250
300
300
350
200
250
250
315
D2h
D2h
D2h
D2h
D4h
D4h
315
395
395
480
473
435
593
528
302
361
361
443
453
397
542
487
218
274
274
333
241
288
288
353
262
313
313
384
304
381
381
463
291
348
348
427
2x185 (2x350 mcm)
550
630
3093
4116
4039
5137
2872
3569
3575
4566
125 (275)
125 (275)
0.98
110 °C
80 °C
N250
HO
NO
250
315
350
450
315
355
D2h
D2h
D4h
480
588
720
647
443
535
665
588
333
407
353
426
384
463
463
567
427
516
800
5005
6674
4458
5714

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AutomationDrive FC 300 and is the answer not in the manual?

Questions and answers

Table of Contents