Selection
FC 302 High/Normal load*
Typical Shaft output at 550 V [kW]
Typical Shaft output at 575 V [hp]
Typical Shaft output at 690 V [kW]
Enclosure IP21
Enclosure IP54
Enclosure IP20
4
4
Output current
Continuous (at 550 V) [A]
Intermittent (60 s overload) (at 550 V)[A]
Continuous (at 575/690 V) [A]
Intermittent (60 s overload) (at 575/690 V)
[kVA]
Continuous kVA (at 550 V) [kVA]
Continuous kVA (at 575 V) [kVA]
Continuous kVA (at 690 V) [kVA]
Maximum input current
Continuous (at 550 V) [A]
Continuous (at 575 V) [A]
Continuous (at 690 V)
Max. cable size: mains, motor, brake and load
share mm
2
(AWG)
Max. external mains fuses [A]
Estimated power loss at 575 V [W]
Estimated power loss at 690 V [W]
Weight, enclosure IP21, IP54 kg (lbs.)
Weight, enclosure IP20 kg (lbs.)
4)
Efficiency
Output frequency
Heatsink overtemperature trip
Control card ambient trip
*High overload=150% current for 60 s, Normal overload=110% current for 60 s.
Table 4.7 Technical Specifications, D-frame, 525-690 V Mains Supply 3x525-690 V AC
1) American Wire Gauge.
2) For fuse ratings, see 7.2.1 Fuses.
3) Typical power loss is at normal conditions and expected to be within
values are based on a typical motor efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the frequency converter. If the
switching frequency is raised from nominal, the power losses rise significantly. LCP and typical control card power consumptions are included.
Options and customer load can add up to 30 W to the losses, though usually a fully loaded control card and options for slots A and B each add
only 4 W.
4) Measured using 5 m screened motor cables at rated load and rated frequency.
62
VLT
1)
2)
3) 4)
3) 4)
®
AutomationDrive FC 300 Design Guide 90-1200 kW
N160
N200
HO
NO
HO
132
160
160
200
250
250
160
200
200
D2h
D2h
D2h
D2h
D4h
D4h
201
253
253
302
278
380
192
242
242
288
266
363
191
241
241
191
241
241
229
289
289
198
245
245
189
234
234
197
240
240
2361
3074
3012
2446
3175
3123
± 15% (tolerance relates to variety in voltage and cable conditions.) These
MG34S202 - Rev. 2013-08-19
N250
NO
HO
NO
200
200
250
300
300
350
250
250
315
D2h
D2h
D4h
303
303
360
333
455
396
290
290
344
319
435
378
289
289
343
289
289
343
347
347
411
299
299
355
286
286
339
296
296
352
2x185 (2x350)
550
3723
3642
4465
3851
3771
4614
125 (275)
125 (275)
0.98
0–590 Hz
110 °C
80 °C
N315
HO
NO
250
315
350
400
315
400
D2h
D2h
D4h
360
418
540
460
344
400
516
440
343
398
343
398
411
478
355
408
339
390
352
400
4146
5028
4258
5155