Danfoss VLT AutomationDrive FC 300 Design Manual page 74

90-1200 kw
Hide thumbs Also See for VLT AutomationDrive FC 300:
Table of Contents

Advertisement

Selection
Max. current
Resolution for analog inputs
Accuracy of analog inputs
Bandwidth
The analog inputs are galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
4
4
Illustration 4.1 PELV Isolation
Pulse/Encoder Inputs
Programmable pulse/encoder inputs
Terminal number pulse/encoder
Max. frequency at terminal 29, 32, 33
Max. frequency at terminal 29, 32, 33
Min. frequency at terminal 29, 32, 33
Voltage level
Maximum voltage on input
Input resistance, R
Pulse input accuracy (0.1-1 kHz)
Encoder input accuracy (1-11 kHz)
The pulse and encoder inputs (terminals 29, 32, 33) are galvanically isolated from the supply voltage (PELV) and other high-
voltage terminals.
1)
FC 302 only
2)
Pulse inputs are 29 and 33
3)
Encoder inputs: 32=A, and 33=B
Analog Output
Number of programmable analog outputs
Terminal number
Current range at analog output
Max. load GND - analog output
Accuracy on analog output
Resolution on analog output
The analog output is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
Control Card, RS-485 Serial Communication
Terminal number
Terminal number 61
The RS-485 serial communication circuit is functionally separated from other central circuits and galvanically isolated from the
supply voltage (PELV).
Digital Output
Programmable digital/pulse outputs
Terminal number
Voltage level at digital/frequency output
Max. output current (sink or source)
Max. load at frequency output
72
VLT
+24V
18
37
Functional
isolation
RS485
i
®
AutomationDrive FC 300 Design Guide 90-1200 kW
PELV isolation
Control
High
voltage
MG34S202 - Rev. 2013-08-19
Max. error 0.5% of full scale
Mains
Motor
DC-Bus
1)
29
110 kHz (Push-pull driven)
5 kHz (open collector)
see 9.2.2 Digital Inputs - Terminal X30/1-4
Max. error: 0.1% of full scale
Max. error: 0.05 % of full scale
Max. error: 0.5% of full scale
68 (P,TX+, RX+), 69 (N,TX-, RX-)
Common for terminals 68 and 69
30 mA
10 bit (+sign)
100 Hz
2/1
2)
3)
3)
, 33
/32
, 33
4 Hz
28 V DC
approx. 4 kΩ
1
42
0/4-20 mA
500 Ω
12 bit
2
1)
27, 29
0-24 V
40 mA
1 kΩ

Advertisement

Table of Contents
loading