Options and Accessories
Safety System Values
EN 61508 for Tu=75 °C ongoing
SIL
HFT
PFD (for yearly functional test)
SFF
λ
s
DD
λ
DU
Ordering number

9.8 MCB 113 Extended Relay Card

The MCB 113 adds 7 digital inputs, 2 analog outputs, and 4 SPDT relays to the standard I/O of the frequency converter,
providing increased flexibility and compliance with the German NAMUR NE37 recommendations.
The MCB 113 is a standard C1-option for the Danfoss VLT
For information on mounting and installing the option, see 9.1.3 Slot C.
1
2
3
4
1
2
1
2
3
4
5
6
X45/
X48/
X46/
Illustration 9.17 Electrical Connections of MCB 113
MCB 113 can be connected to an external 24 V on X58/ in order to ensure galvanic isolation between the VLT
tionDrive and the option card. If galvanic isolation is not needed, the option card can be powered through internal 24 V
from the frequency converter.
NOTICE
It is acceptable to combine 24 V signals with high voltage signals in the relays as long as there is one unused relay in-
between.
To set up MCB 113, use parameter groups 5-1* Digital Inputs, 6-7* Analog Output 3, 6-8* Analog Output 4, 14-8* Options, 5-4*
Relays, and 16-6* Inputs and Outputs.
NOTICE
In parameter group 5-4* Relays, array [2] is relay 3, array [3] is relay 4, array [4] is relay 5, and array [5] is relay 6.
®
VLT
AutomationDrive FC 300 Design Guide 90-1200 kW
®
7
8
9
10
11
12
13 14
MG34S202 - Rev. 2013-08-19
AutomationDrive and is detected automatically after mounting.
2 for maintenance cycle of 2 years
1 for maintenance cycle of 3 years
4.10 *10
8494 FIT
934 FIT
130B1137
®
Automa-
0
-3
78%
9
9
235

Advertisement