Options and Accessories
Electrical Data
Relays
Numbers
Load at 250 V AC/30 V DC
Load at 250 V AC/30 V DC with cos=0.4
Over voltage category (contact-earth)
Over voltage category (contact-contact)
Combination of 250 V and 24 V signals
Maximum thru-put delay
Isolated from ground/ chassis for use on IT mains systems
Digital Inputs
Numbers
Range
Mode
Input impedance
Low trigger level
High trigger level
Maximum through-put delay
Analog Outputs
Numbers
Range
9
9
Resolution
Linearity
Analog Outputs
Numbers
Range
Resolution
Linearity
EMC
EMC
236
®
VLT
AutomationDrive FC 300 Design Guide 90-1200 kW
IEC 61000-6-2 and IEC 61800-3 regarding Immunity of BURST, ESD, SURGE and Conducted Immunity
MG34S202 - Rev. 2013-08-19
Possible with one unused relay in between
4 SPDT
8A
3.5 A
III
II
10 ms
7
0/24 V
PNP/NPN
4 kW
6.4 V
17 V
10 ms
2
0/4-20 mA
11 bit
<0.2%
2
0/4-20 mA
11 bit
<0.2%