Mechanical Installation
6
6
Illustration 6.99 Wall Mounting Spacer
To install a pedestal-mounted D-frame unit, perform the
following steps as shown in Illustration 6.100:
1.
Attach the pedestal to the back channel using 2
M10 nuts.
2.
Fasten 2 M5 screws through the back pedestal
flange into the pedestal drive mounting bracket.
3.
Fasten 4 M5 screws through the front pedestal
flange into the front gland plate mounting holes.

6.2.12 Pedestal Installation of E-frames

As seen in Illustration 6.101 the bottom plate of the E1 can be mounted from either inside or outside of the enclosure. If
bottom mounted, the glands and cables can be mounted before the frequency converter is placed on the pedestal.
Illustration 6.101 Mounting of Bottom Plate, Frame Size E1.
To assemble a pedestal-mounted E-frame unit, install each M10x30 mm bolt with captive lock washer and flat washer
through the base plate and into the threaded hole in the base. Install 4 bolts per cabinet.
158
®
VLT
AutomationDrive FC 300 Design Guide 90-1200 kW
Illustration 6.100 Pedestal Hardware Installation
MG34S202 - Rev. 2013-08-19