A
Diagnostic messages
Error group 16
Initialization
No.
Code
Message
16-3
6183h
Unexpected status / programming error
Cause
Action
Error group 17
Following error monitoring
No.
Code
Message
17-0
8611h
Following error monitoring
Cause
Action
Error group 18
Output stage temperature monitoring
No.
Code
Message
18-1
4280h
Output stage temperature 5 °C below maximum
Cause
Action
Error group 19
I²t monitoring
No.
Code
Message
19-0
I²t at 80 %
2380h
Cause
Action
Error group 21
Current measurement
No.
Code
Message
21-0
5210h
Error, offset current measurement
Cause
Action
Festo – GDCP-CMMS/D-C-CO-EN – 1404NH – English
The software has taken an unexpected status.
For example, unknown status in the FHPP state machine.
• In case of repetition, load firmware again.
If the error occurs repeatedly, the hardware is defective.
Comparison threshold for the limit value of the following error
exceeded.
• Enlarge error window.
• Parameterise acceleration to be less.
• Motor overloaded (current limiter from the I²t monitoring active?).
The output stage temperature is greater than 90 °C.
• Check installation conditions, cooling through the housing
surface, integrated heat sink and back wall.
Of the maximum I²t workload of the controller or motor, 80 % has
been achieved.
• Check whether motor/mechanics are blocked or sluggish.
The controller performs offset compensation of the current
measurement.
Tolerances that are too large result in an error.
If the error occurs repeatedly, the hardware is defective.
• Send motor controller to the manufacturer.
Reaction
PS off
Reaction
configurable
Reaction
configurable
Reaction
configurable
Reaction
PS off
147