5
Device Control
5.1.5

Status words (statuswords)

Object 6041
: statusword
h
Index
Name
Object Code
Data Type
Access
PDO Mapping
Units
Value Range
Default Value
Bit
Value
0
0001
h
1
0002
h
2
0004
h
3
0008
h
4
0010
h
5
0020
h
6
0040
h
7
0080
h
8
0100
h
9
0200
h
10
0400
h
11
0800
h
12
1000
h
13
2000
h
14
4000
h
15
8000
h
Tab. 5.7
Bit allocation in the status word
All bits of the statusword are unbuffered. They represent the current device status.
Festo – GDCP-CMMS/D-C-CO-EN – 1404NH – English
6041
h
statusword
VAR
UINT16
ro
yes
Function
Status of the motor controller (
These bits must be evaluated together.
voltage_enabled
Status of the motor controller (
warning
drive_is_moving
remote
target_reached
internal_limit_active
set_point_acknowledge/speed_0/homing_attained/ip_mode_active
following_error/homing_error
reserved
Drive referenced
Tab. 5.6).