Error Management - Festo CiA 402 Manual

For motor controller
Table of Contents

Advertisement

4
Setting parameters
4.12

Error management

Overview
The motor controllers of the CMMS family offer the option to change the error response of individual
events, e.g. the occurrence of a following error. As a result, the motor controller reacts differently when
a certain event occurs: Depending on the setting, braking down can occur with the output stage being
shut off immediately or a warning being shown on the display.
For every event, a minimum reaction is intended by the manufacturer, which cannot be fallen below.
And so "critical" errors, such as 60-0 short circuit output stage, are not reparametrised, since here an
immediate switch-off is necessary to protect the motor controller from possible destruction.
If a lower error response is entered than is permissible for the respective error, the value is limited to
the lowest permissible error response. A list of all error numbers is found in chapter A
" Diagnostic messages".
Description of the objects
Objects addressed in this chapter
Index
Object
2100
RECORD
h
2100_01
VAR
h
2100_02
VAR
h
Object 2100
: error_management
h
Index
Name
Object Code
No. of Elements
The main error number whose response should be changed must be specified in the object error_num-
ber. This number is the bit number of the internal error bit (range of values 1 ... 64,
Sub-Index
Description
Data Type
Access
PDO Mapping
Units
Value Range
Default Value
Festo – GDCP-CMMS/D-C-CO-EN – 1404NH – English
Name
error_management
error_number
error_reaction_code
2100
h
error_management
RECORD
2
01
h
error_number
UINT8
rw
no
1 ... 64
1
Type
Attr.
ro
UINT8
rw
UINT8
rw
Appendix A).